Hot key 1: Main screen
•
Hot key 2: Temperature screen
•
The temperature hot screen shows important information regarding the status of temperature sensors
attached to the Super Guard. The average temperature (defined in table 6.6) is displayed on the upper
left side and shows the average of temperature sensors T1 through T3. Table 6.2 enables the user to set
the temperature sensor T3 as 'OUT' and therefore T3 presents the outside temperature. On the right side,
you can see the temperature for entering tunnel ventilation mode.
T1
24.4
#01
T2
25.1 AVG.
T3
22.5 TUN.
OUT
Hot key 3: Targets Screen
•
This screen shows all of the target levels, selected for any of the controller's functions.
TARGETS
#01
TEMP
22.5
MIN LEVEL
5
ON
MAX LEVEL
15
OFF
Hot key 4: Curtain Position screen
•
This screen shows the curtain opening position in percent. If for example curtain 2 show 40%, it is
40% open.
CURTAIN POSITION
CURT.1
50
CURT.2
CURT.3
40
CURT.4
TUNNEL
OP
INLET
Hot key 5: Curtain Steps
•
This screen shows the number of steps for each curtain.
CURTAIN STEPS
CURT.1
12
CURT.2
CURT.3
14
CURT.3
TUNNEL
--
INLET
Hot key 6: System Status
•
This screen shows if humidity treatment is ON/OFF, if the cycle is ON/OFF and how many seconds
left for the current cycle.
SYSTEM STATUS
HUMIDITY TREAT.
CYCLE STATUS
CYCLE LEFT
22.9
Room Number
23.3
22.5
PRESS 0.01
60
240
#01
CL
--
--
#01
--
--
--
#01
ON/OFF
ON/OFF
29