• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
• *2: Sound pressure level:
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
™
• *3: Available on Google Play
store or on App Store
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
Rated
Max.
kW
Rated
Max.
Rated
A
%
kW/kW
L/h (pints/h)
A
HIGH
MED
LOW
QUIET
3
m
/h
HIGH
MED
LOW
QUIET
W
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
mm
mm
kg
Liquid
mm (in)
Gas
°C
%RH
°C
Net
mm
Gross
Net
kg
Gross
mm
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
- 4 -
Cassette
Inverter heat pump
AUXG18KVLA
230 V ~ 50 Hz
Outdoor unit
198—264 V
5.20
17,700
0.90—5.90
3,100—20,100
6.00
20,500
0.90—7.50
3,100—25,600
1.60
2.79
1.66
2.79
7.0
7.3
99.4
98.9
3.25
3.61
2.2 (3.9)
12.1
12.1
680
580
490
410
800
680
580
450
Turbo × 1
54
38
34
30
26
43
38
34
30
210 × 1,310 × 13.3
210 × 1,250 × 13.3
1.2
2 × 10
Copper tube
Aluminum
245 × 570 × 570
265 × 730 × 625
15
19
Ø 6.35 (Ø1/4)
Ø12.70 (Ø1/2)
Flare
18 to 32
80 or less
16 to 30
Polystyrene
White
Approximate color of Munsell 9PB 9.1/0.2
49 × 620 × 620
120 × 765 × 755
2.3
4.5
Wired remote controller, Wireless remote controller, Mobile app*3 (FGLair