Safety Devices - Fujitsu AUXG09KVLA Design & Technical Manual

Cassette type
Hide thumbs Also See for AUXG09KVLA:
Table of Contents

Advertisement

11. Safety devices

Type of
Protection form
protection
Circuit
Current fuse (Main PCB)
protection
Fan motor
Terminal protection
protection
program
Terminal protection
program
(Discharge temp.)
Compressor
protection
Thermal protection
program (Outdoor temp.)
(Only in COOL or DRY
mode)
Type of
Protection form
protection
Circuit
Current fuse (Main PCB)
protection
Fan motor
Terminal protection
protection
program
Terminal protection
program
(Discharge temp.)
Terminal protection
Compressor
program
protection
(Compressor temp.)
Thermal protection
program (Outdoor temp.)
(Only in COOL or DRY
mode)
High
pressure
Pressure switch
protection
AOYG09KBTB
250 V, 20 A
125 ±25 °C
Activate
Fan motor stop
100 ±25 °C
Reset
Fan motor restart
Activate
Reset
Activate
Reset
AOYG18KBTB
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
- 77 -
Model
AOYG12KBTB
AOYG14KBTB
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
100 ±15 °C
Fan motor stop
95 ±10 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart
Model
AOYG22KBTB
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
125±10 °C
Fan motor stop
120±10 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
108 °C
Compressor stop
After 3 minutes, and 80 °C or less
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart
+0
4.2
MPa
-0.15
Compressor stop
3.2 ±0.15 MPa
Compressor restart
11. Safety devices

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents