Micro Detectors CR0 Series Installation And Operation Manual

Micro Detectors CR0 Series Installation And Operation Manual

Retroreflective area sensor
Hide thumbs Also See for CR0 Series:

Advertisement

Quick Links

CR0 SERIES
M.D. Micro Detectors
Strada S. Caterina, 235
LANGUAGE
41122 Modena Italy
RETROREFLECTIVE AREA SENSOR
Tel. +39 059 420411
Fax +39 059 253973
Installation and Operation Manual
ENGLISH
www.microdetectors.com
info@microdetectors.com
M.D. Micro Detectors
CAT8ECR1780101
1/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CR0 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Micro Detectors CR0 Series

  • Page 1 CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com M.D. Micro Detectors CAT8ECR1780101 1/16...
  • Page 2: Table Of Contents

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com SUMMARY 1.0 ABOUT THIS DOCUMENT ....................... 3 1.1 Function of this manual ........................3 1.1 Explanation of symbols ........................3...
  • Page 3: About This Document

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 1.0 ABOUT THIS DOCUMENT Please read careful this document before installation, start-up, use and maintenance of CR0 light curtains. This manual contains detailed instructions that must be carefully followed.
  • Page 4: Product Description

    The working distance is 0.2...4.5m with reflector RL106G and lower with smaller reflectors, the best detection capability is 6mm. All models of CR0 series have a teach button (inductive teach could also be available) in the top of the curtain dedicated to the activation of menu functions: two levels of Teach-in and Blanking.
  • Page 5: Functions Description

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 3.3 Functions description 3.3.1 Behavior at power-on Power ON Voltage <5V...
  • Page 6: Teach In

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 3.3.2 Teach in Normal operation Press the Teach button;...
  • Page 7: Beams Exclusion Menu (Blanking) And Restore Factory Setting

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 3.3.3 Beams exclusion menu (blanking) and restore factory setting.
  • Page 8: Electrical Drawing

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 3.1 Electrical drawing REFLEX CR0/0I MODEL SERIE CR0 CURTAIN...
  • Page 9 CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com REFLEX CR0/BN MODEL SERIE CR0 CURTAIN NPN outputs NO and NC...
  • Page 10: Technical Specifications

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 4.0 TECHNICAL SPECIFICATIONS OPTICAL BEHAVIOR PARAMETERS Min. Nom. Max.
  • Page 11 CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com ELECTRICAL MECHANICAL BEHAVIOR PARAMETERS Min. Nom. Max. NOTES Power supply Operatin voltage From PELV power supply according to EN 60204-1 Chap.6.4...
  • Page 12: Start-Up Instructions

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 5.0 START-UP INSTRUCTIONS 5.1 Mechanical mounting of CR models It is extremely important to fix the sensors and the reflectors to a rigid structure, not subject to deformation or to strong vibrations.
  • Page 13: Display Indications And Diagnostics

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 5.4 Display indications and diagnostics. MEANINGS OF LEDs SIGNALLING MODES...
  • Page 14: Mechanical Dimensions Of Light Curtains And Standard Accessories

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 6.0 MECHANICAL DIMENSIONS OF LIGHT CURTAINS AND STANDARD ACCESSORIES 6.1 Mechanical dimensions of CR0/**-1V reflex curtains...
  • Page 15: Installation

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 7.0 INSTALLATION Securing CR0 light curtains with accessories’ kit ST151...
  • Page 16: Control Of The Installed Retroreflective Area Sensor

    CR0 SERIES M.D. Micro Detectors Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual ENGLISH www.microdetectors.com info@microdetectors.com 10.0 CONTROL OF THE INSTALLED RETROREFLECTIVE AREA SENSOR 10.1 Purpose of controls.