Summary of Contents for Micro Detectors CR0 Series
Page 1
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m M.D. Micro Detectors...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com SUMMARY ABOUT THIS DOCUMENT ......................3 Function of this manual ........................3 Explanation of symbols ........................
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m 1.0 ABOUT THIS DOCUMENT Please read careful this document before installation, start before installation, start -up, use and maintenance of CR0 light curtains.
The working distance is 0.2...5m with reflector RL106 and lower with smaller reflectors, the best detection capability is 6mm. All models of CR0 series have a teach button (inductive teach could also be available) in the top of the curtain dedicated to the activation of menu functions: two levels of Teach-in and Blanking.
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com 3.3 Functions description 3.3.1 Behavior at power-on Power ON All LEDs OFF Votage <5V...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com 3.3.2 Teach in Normal operation Press the Teach button;...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com 3.3.3 Beams exclusion menu (blanking) and restore factory setting.
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m 3.1 Electrical drawing...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com REFLEX CR0/BN MODEL SERIE CR0 CURTAIN NPN outputs NO and NC...
Page 10
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com MODELS CR0 ELECTRICAL MCHANICAL PARAMETERS Min. Nom. Max. NOTES...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com 5.0 START-UP INSTRUCTIONS 5.1 Mechanical mounting of CR models It is extremely important to fix the sensors and the reflectors to a rigid structure, not subject to deformation or to strong vibrations.
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m 5.5 Display indications and diagnostics.
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m 6.0 MECHANICAL DIMENSIONS OF LIGHT CURTAINS AND STANDARD ACCESSORIES...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual Installation and Operation Manual www.microdetectors.com www.microdetectors.com ENGLISH info@microdetectors.co m 7.0 INSTALLATION Securing C Securing C R0 light curtains with accessories’...
M.D. Micro Detectors CR0 SERIES Strada S. Caterina, 235 LANGUAGE 41122 Modena Italy RETROREFLECTIVE AREA SENSOR Tel. +39 059 420411 Fax +39 059 253973 Installation and Operation Manual www.microdetectors.com ENGLISH info@microdetectors.com 10.0 CONTROL OF THE INSTALLED LIGHT CURTAINS 10.1 Purpose of controls.
Need help?
Do you have a question about the CR0 Series and is the answer not in the manual?
Questions and answers