Epson EB-805F Installation Manual page 18

Hide thumbs Also See for EB-805F:
Table of Contents

Advertisement

Installing the Wall Mount
Caution
When installing two or more projectors in parallel, leave a gap of at least 1,200 mm between
the projectors.
1200mm
If you cannot secure a gap of approx. 1,200 mm, install a partition to block the heat vented from
the projector's air exhaust vent.
The partitions should be larger than the exhaust vent (approx. 20 mm in all directions), and installed
approximately 400 mm from the exhaust vent and 200 mm from the intake vents.
400mm
200mm
We recommend using stick-on screens or board screens.