3 - Clock gas meter to ensure that the unit is operating at
the specified firing rate for each stage of operation.
Check the supply pressure and the manifold pressure
on both low fire and high fire. If manifold pressure
adjustment is necessary, consult the Service
Literature for unit specific information on adjusting
gas pressure. Not all gas valves are adjustable.
Verify correct temperature rise..
Winterizing and Condensate Trap Care
1 - Turn off power to the furnace.
2 - Have a shallow pan ready to empty condensate
water.
3 - Remove the clean out cap from the condensate trap
and empty water. Inspect the trap then reinstall the
drain plug.
Cleaning the Burner Assembly (if needed)
1 - Turn off electrical and gas power supplies to furnace.
Remove upper and lower furnace access panels.
2- Disconnect the 2-pin plug from the gas valve. Remove
the burner box cover (if equipped).
3- Disconnect the gas supply line from the gas valve.
Remove gas valve/manifold assembly.
4- Loosen clamps and remove combustion air intake
flexible connector (if equipped).
5- Mark and disconnect sensor wire from the sensor.
Disconnect plug from the ignitor at the burner box.
Remove four screws which secure burner box
assembly to vest panel. Remove burner box from the
unit.
6- Use the soft brush attachment on a vacuum cleaner
to gently clean the face of the burners. Visually
inspect the inside of the burners and crossovers for
any blockage caused by foreign matter. Remove any
blockage.
7- Reinstall the burner box assembly using the existing
four screws. Make sure that the burners line up in the
center of the burner ports.
8- Reconnect the sensor wire and reconnect the 2-pin
plug to the ignitor wiring harness.
9- Reinstall combustion air intake flexible connector (if
equipped), secure using existing clamps.
10- Reinstall
the
gas
Reconnect the gas supply line to the gas valve.
Reinstall the burner box cover.
valve
manifold
assembly.
11 - Reconnect plug to gas valve.
12 - Replace the blower compartment access panel.
13 - Refer to instruction on verifying gas and electrical
connections when re-establishing supplies.
14 - Follow lighting instructions to light and operate
furnace for 5 minutes to ensure that heat exchanger
is clean and dry and that furnace is operating
properly.
15 - Replace access panel.
Repair Parts List
Cabinet Parts
Outer access panel
Blower access panel
Top Cap
Control Panel Parts
Transformer
Integrated control board
Door interlock switch
Blower Parts
Blower wheel
Motor
Motor mounting frame
Motor capacitor
Blower housing cutoff plate
Heating Parts
Flame Sensor
Heat exchanger assembly
Gas manifold
Combustion air inducer
Gas valve
Main burner cluster
Main burner orifices
Pressure switch
Ignitor
Primary limit control
Flame rollout switches
Page 48