LG DLEX9000 Series Service Manual page 20

Electric & gas dryer
Hide thumbs Also See for DLEX9000 Series:
Table of Contents

Advertisement

Thermistor of blower
tE1
housing
Thermistor of blower
tE2
housing
Thermistor of steam
tE4
generator
dE
Door SW
E5
Water supply pump
Wire Connection
PS
(Black-White-Red)
EE
EE PROM Error
nC
NFC module
nE
Modem
nF
Wi-Fi module
Outlet thermistor open or shorted.
Outlet thermistor open or shorted.
Steam generator thermistor open
or shorted.
Door SW is abnormal. (only TEST
MODE)
When the pump valve is less than
10 in the test mode
Wire Connection is wrong.
Wire Connection is loose.
EE PROM operation is adnormal.
NFC module open or shorted
Modem is abnormal.
Wifi is is abnormal.
20
• tE1 error is displayed in the
drying cycle or test mode.
• tE2 error is displayed in the
drying cycle or test mode.
• tE4 error is only displayed in the
test mode.
• Replace the steam generator.
• dE error is only displayed in the
test mode.
• tE5 error is only displayed in the test
mode.
• Check the connection between
harness wire and connector.
• Replace the water supply pump.
• verify proper connection of the
power cord. (Electric dryer only.)
* PS means power supply.
• EE error is displayed only in the
test mode
• nC is displayed only in the test mode
• nE is displayed only in the test mode
• nF is displayed only in the test mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents