HMI User panel ......................................14 Moving the user panel ..................................14 Wall bracket ......................................14 Electrical connections unit ..................................15 Compact P unit ....................................15 Electrical connections accessories ................................ 16 User programe 1 ....................................16 Modbus ......................................... 16 External pre-heating element ................................17 Electrical after-heating element ..............................
Page 3
Ventilation installation Duct system ....................................... 32 Legislation ......................................32 Ducts ........................................32 Ventilation unit ....................................32 Extract air ......................................33 Supply air ......................................33 Roof terminals ....................................33 Installation example ..................................33 Balancing ........................................34 Important information ..................................34 Balancing connectors ..................................34 Pressure fall diagram ..................................
Requirements for water quality The hot water tank in the Nilan units is made of steel, which has been given a double enamelling, to ensure an extra long service life. In addition, the tank is equipped with a sacrificial anode as extra protection. It is important that the sacrificial anode is replaced regularly.
The instructions can be downloaded from https://www.nilan.dk/en-gb/frontpage/download. If you have questions regarding installation and operation of the unit after having read the instructions, please contact your nearest Nilan dealer. A list of Nilan dealers is available on www.nilan.dk/forhandlere. ATTENTION The unit must be started up immediately after installation and connection to the duct system.
The heat pump has a reversible cooling circuit, which means that the cooling circuit can be turned and it can cool the supply air in the summer. Compact P can cool the supply air by up to 10 ° C in relation to the outdoor air. Due to the low air exchange, usually 1/2 time per hour, it will not act as an air conditioning system.
The unit 1. Duct connections 11. Pre-heating element (Polar version only) 2. Filter change cover 12. USB-cable (for connecting to PC) 3. Control panel (HMI touch-panel) 13. Condensation drain with water lock 4. Extract air filter 14. 180 l hot water tank 5.
Temperature sensor overview Temperature sensors outside the unit T1: Outdoor air T2: Supply air T4: Extract air after heat exchanger T5: Condenser T6: Evaporator T10: Extract air Temperature sensors outside the unit T7: Supply air after heating element (accessory) Temperature sensors int the hot water tank T11: Top of tank T12: Bottom of tank T14: Supply flow floor heating...
Accessories Electrical pre-heating element for frost protection of the unit If your ventilation unit is not a Polar version with an integral pre-heating element, we recommend that you purchase an external pre-heating element as frost protection of the ventilation unit. During prolonged periods of frost, the high efficiency counterflow heat exchanger will ice up.
It is important to ensure that the ventilation unit does not transfer vibrations to the building. The ventilation unit should therefore be placed on a vibration absorbing material. Nilan can supply effective vibration absorbers to place under the ventilation unit. They are sold in packs of 4.
This should be placed in the outdoor air intake, which will reduce the pollen count in the dwelling. Trolley A Nilan trolley makes it easy to transport the heavy units into the home, without having to carry out heavy lifting yourself with the risk of injury.
Compact P is supplied in one piece on a pallet, packed in cardboard. You can use Nilan lifting trolley, with which the unit can be lifted directly off the pallet and into the building. If the filter box is removed, the unit can be manoeuvred through an ordinary door.
Electrical installation Safety ATTENTION All work must be carried out by qualified persons and in compliance with existing legislation and regulations. ATTENTION It is important that the power is off, if you do work to the electrical components of the unit. It is important to check that wires are not damaged or squeezed during connection and use.
(according to the electrical diagram), where the wires from the front connection are removed. Nilan offers a connection cable with RJ12 connectors of 10 m and 20 m, respectively. It is also possible to customize a cable up to 50 m in length.
Electrical connections accessories User programe 1 User programe 1 is connected via the 8-pin plug mounted on top of the unit. The user programe functions are used to override normal operation. The input signal must come from a potential-free switch. When closed, the function is activated with the settings selected in the control panel under Service / User selection 1.
External pre-heating element It is possible to purchase an external electric pre-heating element for frost protection of the ventilation unit. The electric preheating element is mounted in the outdoor air duct before the unit with the necessary temperature sensor. If it is desired to see the actual outdoor air temperature on the control panel, the temperature sensor T1 / T8 must be led out into the duct before the preheating surface.
Electrical after-heating element An after-heating element is necessary if you want to control the supply air temperature. The electric after-heating element can be purchased for installation in the supply air duct and the necessary sensor amd PCB board are included. ATTENTION The T7 temperature sensor has been installed near the heating element.
sensor If there is a large load change in the home / building, it is advantageous to install a CO sensor to control the air exchange. The CO sensor measures the CO level in the exhaust air, and regulates the ventilation level accordingly. The CO sensor is mounted in the unit as illustrated below: 1.
Page 20
7. Mount the power supply box in the box for automatic. 8. Connects as shown in the electrical diagram below. (pre-drill 2 holes for the screws). 9. Reinstall the counterflow heat exchanger. Remember to reinstall the T4 sensor. For SW version 2.00x or less, the resistor must be mounted in series with a black signal cable For SW version 2.01x and above, do not mount a resistor.
User programe 2 With User programe 2, the same options are achieved as with User programe 1. In addition, you get the option of a relay output that can control e.g. a damper or whatever need one may have to control an external function. User programe 2 potential-free input is connected to TF13 and User programe 2 output is connected to relay R7 on the PCB board.
EM-box (damper solution) If it is desired to run the cooker hood over the ventilation system, it may in some cases be difficult to get enough air for the cooker hood. With an EM box installed and when the cooker hood is in operation, you can regulate the extraction so that less air is extracted out of the other rooms, e.g.
DTBU damper solution If it is desired to run the cooker hood over the ventilation system, it may in some cases be difficult to get enough air for the cooker hood. To solve that challenge, an EM-box solution can be used. However, if there is not enough space in the installation for an EM box, you can alternatively connect a DTBU damper in the duct system, which has the same function, except that it does not have a built-in dirt filter.
Fire thermostat / external fire automation system The ventilation unit can be connected up to an external fire thermostat that will stop the ventilation unit in the event of fire. The same port can be used for connection of an external fire automation system. The control system identifies a broken input signal as fire, and stops.
External heat supply The unit can control an external heat supply, such as electric radiators or an underfloor heating system. This feature is used in the cases where the unit contributes to the heating of the house via a heat pump and / or a after heating element. The room temperature is monitored by the unit's control, which only releases the external heat supply if it cannot heat the home / house to the desired room temperature.
Condensate drain Important information Compact P is supplied with a reinforced 20 mm condensation drain pipe with built-in water lock. ATTENTION Run the condensate drain to the nearest drain, allowing an even fall of at least 1 cm per m.
All work must be performed by qualified personnel and in accordance with relevant legislation and provisions. Nilan's hot water tanks are double-enamelled, ensuring long life. The efficient foam insulation protects against unnecessary heat loss. All connection nozzles for water have 3/4" thread and are located in the tank bottom.
Requirements for water quality The hot water tank in the Nilan units is made of steel, which has been given a double enamelling, to ensure an extra long service life. In addition, the tank is equipped with a sacrificial anode as extra protection. It is important that the sacrificial anode is replaced regularly.
Plumbing connections for accessories Safety group CAUTION Safety group must be installed in connection with hot water tanks. When water is heated to 60 °C, it expands by 2%. A pressured tank could burst without a safety valve keeping excess water out. The safety valve should therefore drip during warming up.
Safety group with anti-scald protection In the control, a temperature limit for the domestic hot water of 65ºC is set as standard. This setting prevents scalding of the users when the hot water tap is opened. When the unit is in cooling mode, the energy is deposited in the hot domestic water tank instead of leading it out of the house. This also means that if the hot water temperature exceeds 65ºC, the unit stops cooling the supply air.
This is to avoid vibrations from the unit being transmitted to the duct system. It will also make it easier to move the unit, which may be necessary during future services of the unit. Nilan can supply Soundflex tubes that you can use as flexible connections between the ventilation unit and the duct system. They will also reduce sounds from the system considerably.
Extract air Install the extract air valves in high-humidity rooms and place them strategically where they can extract humid and vitiated air from the dwelling/building most efficiently. High-humidity rooms are, for example: • Bathroom • Lavatory • Kitchen • Utility room Supply air Install supply air valves in living areas.
Balancing Important information ATTENTION To ensure the ventilation system operates optimally, it is important that it is balanced correctly. We recommend that experts do this. It is important to measure the total supply air and the total extract air. The system must have a minimum vacuum, which means it draw out more air than it blows in.
Emergency operation Emergency operation domestic hot water If an error occurs in the controller or components in the Compact P, and the unit therefore stops, it will not be able to produce domestic hot water. If the installer is not able to come right away or the error happens outside the opening hours, and you therefore cannot contact the in- staller, there is a possibility to get hot water by setting the unit into emergency mode.
Domestic hot water Errors and solutions domestic hot water Problem Possible cause Solution The unit produces insufficient domestic The filters may be blocked so that Change the filters and, if necessary, hot water. insufficient air is reaching the unit. change the filter change period to a shorter Interval.