Page 3
Marca / Trademark / Marque / Merk / Marke / Marca Ravelli Modello / Model / Modèle / Model / Modell / Modelo Magnus Classe di efficienza energetica / Energy Efficiency class /Classe d’Efficacité Énergétique / Magnus Energie-efficiëntieklasse / Energieeffizienzklasse / Clase de eficiencia energética...
Page 4
2. Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4): Magnus, 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Residential space heating appliance fired by wood pellets 4.
Page 5
Type de produit Marchio Trademark Ravelli Marque Modello Magnus Model Modèle L'oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione dell'Unione: The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: L'objet de la déclaration décrit ci-dessus est conforme à...
Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove. For further information and requirements contact your Ravelli-authorised Technical Assistance Centre. All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means, including photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buy- er’s staff, without the express written consent of the Manufacturer.
Remote control: Synthetic Declaration of Conformity (DoC) The manufacturer Aico S.p.A. declares that the Remote Control, with the Ravelli brand and model PNET00003 (Palm Touch) is in conformity with the relevant Union harmonisation legislation: 2014/53/EU (RED), and that the following harmonised standards and/ or technical specifications have been applied: ETSI EN 301 489-3, ETSI EN 301 489-1, EN 60950-1 A11+A1+A12+AC+A2, EN 62479.
Use and maintenance manual Magnus Pag.10 WARRANTY Certificate of warranty Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to: • read the installation, use and maintenance instructions for the product; •...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.11 GENERAL INFORMATION Supply and safe-keeping The manual is supplied in printed format. Keep this manual safe, with the stove, so that the user can consult it easily. The manual is an integral part, for safety reasons, therefore: •...
If the chimney catches fire you must call the fire brigade. ⚠ Only use original spare parts. Any tampering and/or replacements that have not been authorised by Ravelli can pose a danger to the user’s safety. ⚠ In the event of particularly adverse weather conditions, the safety systems could intervene and switch off the stove.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.13 residual description procedure-related information risk Risk of When the stove is running, it may reach high burns temperatures to the touch, especially on its external surfaces. Take care to avoid burns and use the specific tools if necessary.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.14 Obligations and forbidden actions Obligations The user must: • read this instructions manual before performing any operation on the stove; • the appliance must not be used by children under the age of 8 or...
A2 and B. Maintain fuels and other flammables at a suitable distance. Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225-2:2014 standard, or certified DIN PLUS (more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show the name of the producer, the main characteristics and classification according to standards.
The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used. Ravelli reserves the right to make any changes in order to improve product performance.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.17 Measurements Unit of Magnus measurement Height 1351 Width 1035 Depth Weight Technical diagram Magnus CARICO PELLET 48,55 148,5 REVERSIBILE DX O SX 1000 USCITA FUMI Ø100 KIT RUOTE PER MOVIMENTAZIONE POSIZIONE REGOLABILE A 180°...
PESO: Description of operation Ravelli Magnus are appliances for domestic heating powered by wood pellets with automatic loading. They are suitable for use as a secondary heating system or as a support for the main heating system. The heat generated by the combustion of the pellets is diffused in the installation room thanks to the ventilation system as well as by radiation and natural convection.
User training Once installation is complete, the user must always be fully trained in the functions and characteristics of the stove by the technician authorized by Ravelli to ensure optimal and safe use. The training should cover the following topics: •...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.20 Safety devices The stove has been designed and equipped with safety systems to minimize user risks. It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.21 SHIPPING AND INSTALLATION Safety warnings for transportation and installation The stove must be installed by a qualified technician, who must issue a declaration of conformity of the system to the purchaser, taking full responsibility for stove installation and correct operation.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.22 Set-ups for the smoke evacuation system Be careful when building the smoke evacuation system and observe the regulations in force in the country where the stove ⚠ is installed. The Manufacturer will not be held liable for incorrectly sized and non-regulation smoke evacuation systems.
Ravelli shall not be held liable if these precautions are not followed. Requirements for the installation premises The stove installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake connected to the outdoors.
Page 24
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.24 Installation example for a stove/pellet stove This type of installation (See Fig.1) requires an insulated chimney pot, even if the entire conduit is installed inside the building. Besides, the structure must be inserted into a properly ventilated skylight shaft.
Page 25
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.25 This type of installation (See Fig.4) requires an insulated chimney pot, even if the entire smoke conduit is installed outside the Protection from rain building. In the lower part of the chimney there is a "T" type fitting installed with inspection cap.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.29 Positioning of the monobloc The monobloc is supplied with wheels that facilitate the positioning of the chimney. Once you have chosen the location in which to install the monobloc, raise the feet.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.30 CONFIGURATIONS The Magnus monobloc allows two different configurations: right (factory configuration) and left. Here are the steps to switch from right to left configuration. Ash drawer, cleaner and card 1. DISASSEMBLY (FROM RIGHT)
Page 31
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.31 SE NON SPECIFICATO: FINITURA: INTERRUZIONE NON SCALARE DISEGNO REVISIONE QUOTE IN MILLIMETRI BORDI NETTI FINITURA SUPERFICIE: TOLLERANZE: LINEARE: ANGOLARE: NOME FIRMA DATA TITOLO: DISEG. VERIF. APPR. FABB. MATERIALE: M0001JR00 Qual. N. DISEGNO...
Page 32
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.32...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.34 Door 1. DISASSEMBLY (FROM RIGHT) SE NON SPECIFICATO: FINITURA: INTERRUZIONE QUOTE IN MILLIMETRI BORDI NETTI NON SCALARE DISEGNO REVISIONE FINITURA SUPERFICIE: TOLLERANZE: LINEARE: ANGOLARE: NOME FIRMA DATA TITOLO: DISEG. VERIF. APPR. FABB.
Page 35
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.35 2. ASSEMBLY (TO LEFT)
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.36 COATING Minimum (internal) dimensions of the coating The cladding built around the chimney must comply with the following minimum internal measures: Minimum measures 1550 mm 700 mm 2000 mm * distance from the front glass to...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.37 CONNECTIONS The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer. By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75 Connection with external air intake The stove has been designed for hermetic installations.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.38 ⚠ Ducting and ventilation Comply with the standards and laws in force in the region where the product is installed. Connect a 80 mm diameter pipe to the stove outlet of the ducting to heat another room of the home. The size of the duct (length and shape) must take into consideration the residual head of the fan of the ducting.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.39 Testing and commissioning Stove start-up must be preceded by testing, which includes an operational check of the following elements: • connection to the smoke evacuation system; • electrical connections; • checking that all materials used to build the smoke duct, chimney and chimney pot are regulation and suitable for use.
Stove on/off button Handheld touch radio initialization The handheld, after a first short screen showing the Ravelli logo, will list the languages available in the menu. Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.41 Description of the handheld set The PDA looks like the following picture: The information below will familiarize you with the product and give you the best performance. Increase button “UP” (selection key) Decrease key “DOWN”...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.42 Vers. 01 of:07.04.14 User’s manual HANDHELD TOUCH RADIO Pag.21 The display is subdivided into three parts: After 5 minutes of inactivity, the handheld display dims to “SLEEP” mode while maintaining the radio connection to the stove.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.43 ⚠ PPROCEDURES FOR USE If the chimney catches fire you must call the fire brigade immediately. ⚠ Checks prior to start-up You have read and perfectly understood the contents of this instructions manual.
If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc ⚠ ...), so please contact a Ravelli CAT. The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new ⚠...
Page 45
Pag.30 If the type of system designed requires controlling the 3-way valve (diagram 1 and 3), it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer. Stove State Stove State Combustion regulation is an operation that requires a lot of experience.
Page 46
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.46 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.30 Stove status Stove State Below are given the steps for accessing the relative menu starting from “Home” mode. Below are given the steps for accessing the relative menu starting from Stand-By mode.
ENABLE COMFORT COMFORT CLIMA ENABLE COMFORT Rev.1 21/04/2021 Use and maintenance manual Magnus ENABLE COMFORT Pag.47 RESTART DELTA SHUTDOWN DELAY COMFORT CLIMA COMFORT CLIMA COMFORT CLIMA DELTA COMFORT CLIMA DELTA In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove.
Page 48
SETUP CONTRAST. “confirm” to “confirm” Rev.1 21/04/2021 “selection” to switch SETTINGS access the Use and maintenance manual Magnus to access the function to the function SETUP CONTRAST. Pag.48 Use the UP/DOWN keys to change the WINTER/ SETTINGS By pressing the following key you will confirm of data SUMMER season.
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.49 Double ducting This function allows you to manage distribution of warm air between the room where the stove is installed and the rooms where the duct arrives. The function has two operating modes: manual and automatic.
Page 50
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.50 Use the “UP” and “DOWN” keys to change the distribution of hot air between right and left ducting (the data is saved without further confirmation). You can choose from five different positions.
Page 51
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.51 To go back to the T.REAR RIGHT menu, press the “back” key. To go back to the T.REAR LEFT menu, press the “increase” key. Use the “confirm” button to enable / disable the external thermostat.
Page 52
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.52 Display of double ducting status The following are the steps to be followed to access the status display, starting from the “Home” screen. CANALIZED MENU USER MANAGEMENT USER CANALIZED TEMPERATURE TECHNICIAN LOADING AUGER...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.53 Stove phase general layout PHASE DESCRIPTION The stove is in the switch off phase and the cooling phase has FINAL CLEANING not been completed yet. The heater pre-heating phase has started and the pellets start to IGNITION fall into the grate.
Page 54
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.54 The stove has detected an anomaly; refer to the troubleshooting ANOMALY (general) chapter. By pressing the confirmation key, the problem is described. AUTOMATIC CLEANING For models with automatic cleaning system it indicates the SYSTEM ACTIVE operating state of the same.
Page 55
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.55 The flue is blocked. Check the flue is free and clean AL 08 DEPRESSION The vacuum meter is faulty. Check the mains voltage. FUME The fume exhaust system has a loss of...
Page 56
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.56 Wifi kit WIFI MODULE MOTHERBOARD (STOVE) Wifi external power supply kit (if applicable) WIFI MODULE MOTHERBOARD (STOVE) BOARD WITH CONNECTORS FOR EXTERNAL POWER SUPPLY CONNECTION EXTERNAL POWER SUPPLY WITH MICRO USB CONNECTOR...
(ESEMPI A e B) ATTENZIONE! ATTENZIONE! Eseguire questa operazione esclusivamente ad apparecchio freddo INSTALLATION QUICK GUIDE RAVELLI SMART WI - FI Eseguire questa operazione esclusivamente ad apparecchio freddo e con spina elettrica disinserita. Connect the WiFi module cable e con spina elettrica disinserita.
Page 58
CONNECTION TO THE WiFi NETWORK Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.58 Click in succession > Networks. The Select wifi network screen will appear. Click Scan for networks: Connection to the WiFi network select your WiFi network and enter the password if required. Close the Click in succession >...
Deactivate the WiFi connection on your device, open the App and Rev.1 21/04/2021 Use and maintenance manual Magnus click Access to cloud. Select Register your account, enter the required Pag.59 information (the name must not contain spaces) and click Register.
Page 60
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.60 STEP 2 enter the product serial number and give the module a name living room stove); STEP 2 enter the product serial number and give the module a name (e.g. living room stove);...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.61 MAINTENANCE ⚠ Safety warnings for maintenance Maintenance of the stove must be performed at least once a year and should be planned in advance with the Technical ⚠ Assistance Service. In some conditions, such as turning the stove on and off or inappropriate use, the combustion products can contain small soot particles that build up in the smoke evacuation system.
Schedule the above extraordinary maintenance activities with the Authorised Assistance Centre. Deep combustion chamber cleaning This operation must be carried out by a Ravelli Assistance Centre. Schedule this type of cleaning with the Ravelli Assistance Centre. To clean the combustion chamber, proceed as described below: After cleaning the combustion chamber, it is advisable to proceed with the cleaning of the inspection hatches as indicated in the para- graph “Smoke duct cleaning”.
Page 63
Checking the seals This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre. When thoroughly cleaning the stove, the authorised technician must check that the gaskets of - port - hatches are intact.
Page 64
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.64 SE NON SPECIFICATO: FINITURA: INTERRUZIONE QUOTE IN MILLIMETRI BORDI NETTI NON SCALARE DISEGNO REVISIONE FINITURA SUPERFICIE: TOLLERANZE: SE NON SPECIFICATO: FINITURA: QUOTE IN MILLIMETRI LINEARE: ANGOLARE: FINITURA SUPERFICIE: TOLLERANZE: NOME FIRMA DATA...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.65 Failure cases Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty Load the pellets into the tank AL 06 Empty the tank to check that no objects have...
Page 66
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.66 Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty. Load the pellets into the tank AL 06 AL 05 Pellet is not loaded See previous problem AL 06...
Page 67
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.67 Problem Causes Possible remedies Alarm signal Remote control not associated Pair the remote control to the stove following with the stove the instructions given here Evaluate the presence of other radio devices...
Rev.1 21/04/2021 Use and maintenance manual Magnus Pag.68 STORAGE AND DISPOSAL Disposal Demolition and disposal of the stove is under the exclusive liability and responsibility of the owner who must do so in accordance with the laws in force in the country of installation pertaining to safety, respect and protection of the environment.
Page 69
ITA-Informazioni per la gestione di rifiuti di apparecchiature elettriche ed elettroniche contenenti pile e accumulatori Questo simbolo che appare sul prodotto, sulle pile, sugli accumulatori oppure sulla loro confezione o sulla loro documentazione, indica che il prodotto e le pile o gli accumulatori inclusi al termine del ciclo di vita utile non devono essere raccolti, recuperati o smaltiti assieme ai rifiuti domestici.
Page 70
ESP-Información para la gestión de residuos de aparatos eléctricos y electrónicos con pilas y acumuladores Este símbolo que aparece en el producto, en las pilas, los acumuladores o en su embalaje o su documentación indica que el producto y las pilas o acumuladores que contiene, al final de su vida útil, no deben recogerse, recuperarse o desecharse junto con los residuos domésticos.
Page 72
Aico S.p.A. Headquarter Via Consorzio Agrario, 3 - 25032 Chiari (BS) - Italy Research and Development Centre Viale del commercio 12/a - 37135 Verona (VR) - Italy T. + 39 030 7402939 info@ravelligroup.it FB Ravellifuocointelligente IG ravellistufe www.ravelligroup.it Aico S.p.A. does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice.