• The sensor must be firmly fastened in order not to vibrate.
• The sensor must not be placed directly behind a panel or any kind of material.
• The sensor must not have any object likely to move or vibrate in its sensing field.
• The sensor must not have any fluorescent lighting in its sensing field.
Wall mounting
1
MOUNTING & WIRING
1
Remove the bracket from the
sensor. Drill 2 holes accordingly.
Mount the bracket firmly.
2
MOUNTING ADJUSTMENT
1
Adjust the angle of the sensor to position the detection field.
FALCON (mtg ht: 16 ft)
Page 2 of 4
Page 2 of 4
INSTALLATION TIPS
DIMENSIONS (inches)
Ceiling mounting
2
Position the sensor on the bracket
and fasten the screws firmly.
CEILING
WALL
FALCON XL (mtg ht: 8 ft)
3
Connect the wires to the door controller.
Choose between NO and NC contact.
European wire color
2
Adjust the field size with the remote
control or the push buttons.
FALCON WIDE (mtg ht: 11.5 ft)
75.5835.05 FALCON FAMILY 20190822
75.5835.05 FALCON FAMILY 20190822
Bracket dimensions
RED
12-24
BLACK
VAC/VDC
WHITE
COM
GREEN
NO
YELLOW
NC
US 
 EURO
cross-reference:
red 
 green
black 
 brown
white 
 white
green 
 yellow
yellow 
 gray
0-9
All detection field
dimensions were measured
in optimal conditions and
with field size value 9.