PEAKTRONICS
The Peaktronics 2nd generation DHC-100 is a high
performance digital positioner intended to control AC actu-
ators, providing 450 points of resolution with quarter turn
actuators ranging from 2 sec to 120 sec and rated for 25%
duty or more. The DHC-100 has many automatic advanced
features that will enhance any actuator while making it easy
to install and set up.
The simple three button control is used to configure
all parameters the unit needs for a wide variety of applica-
tions, and allows the open and closed positions to be easily
set for direct or reversing acting without any rewiring. The
unit can be configured for various command types (4-
20mA, 1-5V, 0-5V, 0-10V, 2-10V, or a Digital command)
and its default operation upon loss of command.
Various option modules are easily plugged into the
unit, providing other features such as a position feedback
signal (current or voltage), auxiliary switches, fault relay
contact, or digital communications. A wide range of data is
accessible through a digital communications module,
providing additional control or information.
The unit is of single solid construction and is easily
mounted with two screws. The DHC-100 is interchangea-
ble with the AMC and LRC standard size controllers, and
can be used to upgrade performance for those applications.
Positions to ±0.1 with quarter-turn actuators ranging from 2 sec to 120 sec (with or
without a brake).
Adaptive Control feature continuously adjusts for load and actuator conditions and
eliminates calibration procedures and auto-cal operations.
Three button control provides easy setup and eliminates the need for instrumentation.
Polarity Detection feature allows direct or reverse acting operation without re-wiring.
Electronic Brake feature can eliminate need for a mechanical brake in many applica-
tions, and extends mechanical brake life when used.
Stall Detection feature protects actuator motor from a stall condition.
Automatic Duty Cycle Control feature prevents shutdown of a process due to a ther-
mal overload of the actuator motor, and allows actuators rated for 25% duty or more to
be safely used.
Operating temperature range of 0 to 60C
Digital High-Resolution Controller
FEATURES
DHC-100
DHC-100
117VAC
DHC-100A
234VAC
DHC-100B
24VAC
U.S. Patent 7,466,100 applies to this product

Advertisement

Table of Contents
loading

Summary of Contents for Peaktronics DHC-100

  • Page 1 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for 25% duty or more. The DHC-100 has many automatic advanced features that will enhance any actuator while making it easy to install and set up.
  • Page 2: Electrical Connections

    DHC-100 OUTLINE DHC-100 DHC-100A DHC-100B 117VAC 234VAC 24VAC PEAKTRONICS Digital High Resolution ELECTRICAL DIGITAL AUTO CONNECTIONS 4-20mA MANUAL / FB POT CAL 1-5VDC CLOSE LAST (BOTH OFF) 0-5VDC OPEN to Motor MODE 0-10VDC AUX CLOSE OUTPUT MOTOR 1 OUTPUT 2-10VDC...
  • Page 3: Block Diagram

    AMC-100, AMC-101 and applied. AC power should be disconnected and antistatic LRC-101 series controllers - the DHC-100 can be used as a measures should be taken prior to any wiring of these direct replacement for those units in nearly any application.
  • Page 4: Override Mode

    DHC-100 POWER / SIGNAL (J2) tion of the DHC-100 and must be installed if the external override functions are not used. Power is connected to pins 1, 2, and 3 as shown in the block diagram. The fuse installed on the unit is rated...
  • Page 5 (▲ and ▼) without affecting any other settings with- off, which also unlatches the OPEN or CLOSE functions. in the DHC-100. When the ▲ button is pressed, the mo- Note that the OPEN and CLOSE functions may tor winding connected to J1-1 is turned on while the ▼...
  • Page 6: Command Type

    1-5V input), 10.5V (for 2-10V ipnut), or 21mA. If the output on the optional relay module - the output can be DHC-100 detects a loss of the command, a fault will be used to drive an alarm or merely act as an auxiliary limit indicated (see FAULT INDICATORS), and the actuator switch.
  • Page 7: Fault Indicators

    Motor 1 output only, and the fault is cleared when the 20mA (for a current output). The new setting is saved DHC-100 detects a motion greater than 1.5 in either di- when the MODE button is pressed. rection. The fault can be cleared if 1) the command signal...
  • Page 8: Specifications

    Control feature of the DHC-100 automatically com- DHC-100, and it prevents disruption of a process due to a pensates for changes in a mechanical brake's performance thermal switch shutdown.
  • Page 9: Power Supply Outputs

    Various option modules can be plugged into the Contact the factory for the latest available modules. Refer DHC-100 option module connector, J3. Option modules to the diagram below for instructions on installing an op- provide additional features such as position feedback sig- tion module.
  • Page 10: Wiring Diagrams

    DHC-100 WIRING DIAGRAMS Input Signal Configurations J2-6 0-5V VOLTAGE CMD (+) 1-5V 0-10V DHC-100 DHC-100 J2-5 2-10V 4-20mA J2-4 Sourcing SIGNAL GND 4-20mA Sinking J2-4 output SIGNAL GND 4-20mA Input using a self powered transmitter Voltage Input using digital-to-analog card...
  • Page 11 DHC-100 WIRING DIAGRAMS Special Applications DHC-100 Voltage Feedback Monitor 7 Voltage Output OTR-100 6 mA Output OTX-100 mA Feedback Monitor 5 GND (Option Module) 4 AUX Close Output 3 AUX Open Output NOTE: The Fault Output contact will 2 Fault Output...
  • Page 12 DHC-100 WIRING DIAGRAMS Special Applications (continued) MECHANICAL AMM-100 USING MANUAL OVERRIDE MOMENTARY SWITCH Series (optional) SWITCHES STOP (optional) J7-1 AUTO J7-2 OFF (optional) Connect for latching function. Note, one STOP switch will MANUAL be required. MECHANICAL AMM-100 USING MANUAL OVERRIDE...

This manual is also suitable for: