ODD-100MS | ODD-100S
INSTALLATION GUIDE

Connect Electrical Wiring

Run 120V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house
wiring to the wiring plate. Refer to the wiring diagram below, and connect the wires as shown.
Wiring Diagram for both ODD-100MS and ODD-100S
info@ortechindustries.com
www.ortechindustries.com

Retrofit Installation

1. Remove wire panel and blower assembly before installation
2. Fold mounting ears flat against housing
3. Enlarge ceiling opening to 9-1/2" by 9-1/2".
Leave ductwork and wiring in place
4. Connect wiring according to the WIRING DIAGRAM on page
this page of this instruction manual.
Re-install wire panel
5. Mounting Fan:
a) the interior of the fan housing contains additional
a)
mounting holes in case exterior mounting is not possible.
a)
Screw or nail the fan housing directly to the framing or
a)
joists. Remove the blower assembly as directed in the
a)
service parts on the very last page of this instruction
a)
manual to gain access to the additional mounting holes
b) Mount with Hole of the Flange:
b)
Use screws (included) to screw fans to the ceiling
b)
through the holes of the housing
6. Connect Duct:
Pull existing ducting through housing discharge opening and
tape ducting to duct connector. Push connector / ducting
back through opening, fix the duct by the tab
7. Install the blower assembly
13376 Comber Way