Maintenance; Inspection And Maintenance; Repair - AWG Z2 Operating Manual

Inductors din 14384 type s and type l
Table of Contents

Advertisement

Available languages

Available languages

AWG I Operating manual I Fittings I
6.2.3
ADVANCED Inspection every 12 months
Check the coupling torque of the Storz adapter:
Threshold value Storz 52 (C): 1.5 Nm
If the coupling torque is below the applicable threshold value, the
adapter must be replaced.
Threaded version: Check the thread for heavy wear and tear.
Replace device if worn.
7

MAINTENANCE

7.1

Inspection and maintenance

Apart from the visual inspection and cleaning of the AWG Inductors, no
regular maintenance work is required.
7.2

Repair

Any repair work on the AWG Inductors may only be performed by the
AWG Fittings GmbH customer service or by an authorised specialist
workshop.
If you need technical support, please contact our Service Centre:
AWG Fittings GmbH
Service Centre
D-89177 Ballendorf
Telephone: +49 (0) 73 40 / 91 88 98 880
Email: awg-service@idexcorp.com
We will accept devices in need of repair or maintenance, discuss with
you the quickest and cheapest solution, create cost estimates, take
care of the execution of the repair work and are at your disposal for
any questions.
M1061B10 I Rev. 01-02/20
Inductors FD Z2 and Z4
Storz 75 (C): 2.5 Nm
ENGLISH
MAINTENANCE
37 / 40