ABB A155-M57 Operation Manual page 86

Hide thumbs Also See for A155-M57:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A150-M56/66/57/67 -
A155-M..
6 Periodic maintenance work / 6.4 Cleaning components mechanically
CAUTION
Water and dirt in the cartridge group
If water or dirt enters the cartridge group, this can impair the function of
the turbocharger and damage parts inside the cartridge group.
Make sure that no water or dirt enters the gap between partition wall and
u
turbine.
CAUTION
Non-permissible rotor unbalance after cleaning
Unevenly distributed residual contamination deposits lead to rotor unbal-
ance. This can result in bearing or turbocharger damage.
Remove all traces of contamination from the turbine.
u
After brushing off the dirt, fill the container (02) with clean water and not with salt water .
u
Immerse the turbine of the cartridge group in clean water so that any loose dirt comes
u
off.
Lift up the cartridge group and align it horizontally.
u
Clamp the partition wall to the bearing casing.
u
Dry the turbine and the gap between the turbine and the partition wall with low-pressure
u
compressed air.
Lightly spray the turbine and the gap between the turbine and the partition wall with pen-
u
etrating oil.
Dispose of dirty water and cleaning agents in accordance with the information in the ma-
u
terial safety data sheet.
© Copyright 2020 ABB. All rights reserved.
HZTL4032_EN
Rev.P
March 2020