Operation - Laserworld SwissLas Purelight Series Manual

Hide thumbs Also See for SwissLas Purelight Series:
Table of Contents

Advertisement

Available languages

Available languages

PL-31.000RGB
key switch
connection for power
supply

8. Operation

1.
Please notice:
Always connect the device to the power supply first before connecting it to the grid.
Make sure that your device is provided with the correct voltage. Wrong voltage could
lead to irreparable damages. Please find the correct voltage data in the synoptical table
at the end of this manual. It must be ensured that the device is not directed to people or
inflammable objects during installation.
The "Power" diode on the rear side of the device begins to light up after the device
has been connected to the power supply.
2.
ILDA in / ILDA out
The device can be controlled via ILDA control signal. There are a ILDA-in (ILDA
input) and a ILDA-out (ILDA output) interface on the rear side of the device.
Connect the laser system to the control interface (DAC) by using an ILDA cable. Do not
connect the laser to standard parallel port at your computer, but always use an appropri-
ate ILDA interface (usually is sold together with the laser control software). After that you
are able to control your laser by a showlaser software (e.g. Phoenix or Pangolin). Use the
ILDA-out interface to daisy-chain the signals (from ILDA-in) to a further device.
Indicating LEDs for power,
overheat & interlock
trim pots for
x / y shift
ILDA out
ILDA in
trim pots
for color
adjust-
ments