Daikin Altherma 3 H HT F+W User Reference Manual page 8

Hide thumbs Also See for Altherma 3 H HT F+W:
Table of Contents

Advertisement

2
|
Quick actions
User reference guide
8
To change the desired leaving water temperature
You can use the leaving water temperature setpoint screen to read out and adjust
the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
2
Main zone
3
Additional zone
2 Adjust the desired leaving water temperature.
a
2
35
°C
Main zone
a
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
To change the weather-dependent curve for the space heating/cooling zones
1 Go to the applicable zone:
Zone
Main zone – Heating
Main zone – Cooling
Additional zone – Heating
Additional zone – Cooling
2 Change the weather-dependent curve.
There are 2 types of WD curves: slope-offset curve (default), and 2-points
curve. If needed, you can change the type in [2.E] Main zone > WD curve
type. The way to adjust the curve depends on the type.
b
+
b
+
[2.5] Main zone > Heating WD
curve
[2.6] Main zone > Cooling WD
curve
[3.5] Additional zone > Heating
WD curve
[3.6] Additional zone > Cooling
WD curve
Go to ...
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT F+W
4P586456-1 – 2019.07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents