You can use the leaving water temperature setpoint screen to read out and adjust
the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
2
Main zone
3
Additional zone
2 Adjust the desired leaving water temperature.
a
2
35
°C
Main zone
a
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
If scheduling is on after changing the desired leaving water temperature
The temperature will stay the same as long as there is no scheduled action.
The desired leaving water temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off scheduling.
To turn off leaving water temperature scheduling
1 Go to one of the following:
[2.1]: Main zone > Schedule
[3.1]: Additional zone > Schedule
2 Select No.
To enable weather-dependent operation for the leaving water temperature
See
"4.9.4 Using weather-dependent
b
+
b
+
4
curves" [
 51].