Page 1
Ingersoll-Rand Company in this manual is historical or nominative 1293 Glenway Drive in nature, and is not meant to suggest a current affiliation between Statesville, N.C. 28625 Ingersoll-Rand Company and Doosan Company or the products of www.doosanportablepower.com either. Book: 46553434 (3-2010) Rev A...
Page 6
Operating & Maintenance Manual Foreword Foreword The contents of this manual are considered to be proprietary and confidential to Doosan Infracore Portable Power (herein referred to as “Portable Power”), and should not be reproduced without the prior written permission of Portable Power.
Page 7
Foreword Operating & Maintenance Manual This machine should not be used: A. For direct or indirect human consumption of the compressed air. B. Outside the ambient temperature range specified in the general data section of this manual. C. When an actual or foreseeable risk of hazardous levels of flammable gases or vapors exists.
Page 10
Operating & Maintenance Manual DRAWBAR NOTICE Sketch). DRAWBAR NOTICE (Important) 8. Temporarily support drawbar and move jack from front of compressor to side of This machine may have been shipped from drawbar. the factory with the drawbar positioned upright. To Convert From Shipping Position to Towing Position The following tools are required: Ratchet...
Operating & Maintenance Manual Safety Safety Precautions General Ensure that the operator reads and understands the decals and consults the manuals before maintenance or operation. Ensure that the Operation and Maintenance manual, and manual holder if equipped, are not removed permanently from the machine. Ensure that maintenance personnel are adequately trained, competent and have read the manuals.
Page 15
Safety Operating & Maintenance Manual Never operate the engine of this machine inside a building without adequate ventilation. Avoid breathing exhaust fumes when working on or near the machine. Do not alter or modify this machine. A battery contains sulfuric acid and can give off gases which are corrosive and potentially explosive.
Page 17
Safety Operating & Maintenance Manual Steps for determining correct load limit - 1. Locate the statement “The weight of cargo should never exceed xxx kg or xxx lbs” on your vehicle’s placard. 2. This figure equals the available amount of cargo and luggage load capacity. 1.
Page 20
Operating & Maintenance Manual Safety Look for these signs on machines shipped to markets in North America, which point out potential hazards to the safety of you and others. Read and understand thoroughly. Heed warnings and follow instructions. If you do not understand, inform your supervisor. DANGER DANGER (Red Background) indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Page 22
Operating & Maintenance Manual Safety Table 1: FREE SAFETY DECALS Safety Decals are available free of charge. Safety Decals are identified by the decal heading: DANGER, WARNING, or CAUTION. Decal part numbers are on the bottom of each decal and are also listed in the compressor’s parts manual.
Operating & Maintenance Manual Noise Emission Noise Emission This section pertains only to machines distributed within the United States. WARNING Tampering with Noise Control System Prohibited Federal law prohibits the following acts or the causing thereof: 1. The removal or rendering inoperative by any persons, other than for purposes of maintenance, repair, or replacement, of any device or element of design incorporated into any new compressor for the purpose of noise control prior to its sale or delivery to the ultimate purchaser or while it is in use;...
Noise Emission Operating & Maintenance Manual Noise Emission Control Maintenance Log COMPRESSOR MODEL __________________________ SERIAL NO. ___________________________________ USER UNIT NO. ________________________________ UNIT IDENTIFICATION DEALER OR DISTRIBUTOR FROM WHOM PURCHASED: Engine Make & Model: ________________ __________________________________ Serial No.: _________________________ __________________________________ Purchaser or Owner: _________________ __________________________________ Address: __________________________ Date Purchased: ____________________...
Page 26
Operating & Maintenance Manual Noise Emission deformed, such that their noise containment function is reduced, should be repaired or Maintenance Schedule replaced before the next operation interval. Item Area Period Doors, access panels, and hatch closures Compressed Air Leaks As Detected especially, should be checked and adjusted Safety and Control Systems As Detected...
Page 27
Noise Emission Operating & Maintenance Manual Maintenance Record For Noise Emission Control And Extended Warranty Item Hourmeter Maint/inspect Location Work Done Description Of Work Reading Date City/state By (Name) Book: 46553434 (3-11-2010) Rev A...
36899698 PRO-TEC Compressor Fluid (1 gal) WARNING Modification or alteration of this machine. Can result in severe injury or death. Do not modify or alter without the express written consent of Doosan Infracore Portable Power. Book: 46553434 (3-11-2010) Rev A...
Page 32
Operating & Maintenance Manual GENERAL DATA Book: 46553434 (3-11-2010) Rev A...
Operating & Maintenance Manual OPERATION BEFORE TOWING WARNING Failure to follow these instructions CAN cause severe injury or death. • Assure tow vehicle has towing capacity for weight of this unit as stated on general data decal. • Position the tow vehicle to align its hitch with the pintle eye or coupler of the compressor.
Page 35
OPERATION Operating & Maintenance Manual SETTING UP (ALL UNITS) • Position as level as possible. The design of these units permits a 15 degree sidewise limit on out-of-level operation. • When the unit is to be operated out-of-level, it is important: 1.
Page 36
Operating & Maintenance Manual OPERATION CONTROL PANEL 1. Compressor Discharge Pressure Gauge - Indicates pressure in receiver tank, psi (kPa). 2. Hourmeter - Records running time for maintenance. 3. Power Switch - Rotate to “ON” to activate system prior to Starting. Rotate to “OFF” to stop engine.
Page 37
OPERATION Operating & Maintenance Manual Before Starting • Open service valve(s) to ensure pressure is relieved in receiver-separator system. Close valve(s) in order to build up full air pressure and ensure proper oil circulation. • Check battery for proper connections and condition. •...
Page 38
Operating & Maintenance Manual OPERATION • WARNING Unrestricted air flow from a hose will result in a whipping motion of the hose which can cause severe injury or death. A safety device must be attached to the hose at the source of supply to reduce pressure in case of hose failure or other sudden pressure release.
Page 39
OPERATION Operating & Maintenance Manual Stopping NOTICE Whenever the machine is stopped, air will flow back into the compressor system from devices or systems downstream of the machine unless the service valve is closed. Install a check valve at the machine service valve to prevent reverse flow in the event of an unexpected shutdown when the service valve is open.
Page 40
Operating & Maintenance Manual OPERATION NOTICE Do NOT wire around or bypass a shutdown sensor or switch. Book: 46553434 (3-11-2010) Rev A...
Page 41
OPERATION Operating & Maintenance Manual P185WYM Speed and Pressure Regulator Adjusting Instructions Before Starting 1. On the Pressure Regulator, loosen the jam nut and turn screw counterclockwise until tension is no longer felt at the screw. Then, turn screw clockwise one full turn. 2.
Page 42
Operating & Maintenance Manual OPERATION Small Electronic Control Unit (SECU) - Display Panel 1. High A/E Temperature: Indicates shutdown due to high compressor temperature. 2. High Separator Temperature: Indicates shutdown due to high temperature at separator tank discharge. 3. Low Battery Voltage: Alarm indicator. Indicates battery or charging system requires service.
C to 52 Alternate: ISO Viscosity Grade 46 with rust Preferred Fluids - Use of these fluids with and oxidation inhibitors, designed original Doosan/Ingersoll Rand branded for air compressor service. filters can extend airend warranty. Refer to 350 psi Preferred:...
Operating & Maintenance Manual MAINTENANCE Maintenance CAUTION Any unauthorized modification or failure to maintain this equipment may make it unsafe and out of factory warranty. If performing more than visual inspections, disconnect battery cables and open manual blowdown valve. Use extreme care to avoid contacting hot surfaces (engine exhaust manifold and piping, air receiver and air discharge piping, etc.).
MAINTENANCE Operating & Maintenance Manual Air Cleaner If this unit is equipped with the Optional Full Instrumentation, the SECU Module, located inside front panel near instrument panel, will Display #9 when either engine or compressor air filter is restricted. Weekly squeeze the rubber valve (precleaner dirt dump) on each air cleaner housing to ensure that they are not clogged.
Operating & Maintenance Manual MAINTENANCE Tires A weekly inspection is recommended. Tires that have cuts or cracks or little tread should be repaired or replaced. Monthly check the wheel lug nuts for tightness. Fasteners Visually check entire unit in regard to bolts, nuts and screws being properly secured. Spot check several capscrews and nuts for proper torque.
Page 49
MAINTENANCE Operating & Maintenance Manual Premature wear of both the engine and compressor is ASSURED whenever dust-laden air is permitted to enter the engine’s combustion chamber or compressor intake. The flexible hoses used in the fuel, oil and air lines on these units are primarily used for their ability to accommodate relative movement between components.
Operating & Maintenance Manual MAINTENANCE NOTICE Installing a new oil filter element when the old gasket remains on the filter head, will cause an oil leak and can cause property damage. 4. Lubricate the new filter gasket with the same oil being used in the machine. 5.
MAINTENANCE Operating & Maintenance Manual Receiver-Separator Systems WARNING High pressure air can cause severe injury or death from hot oil and flying parts. Always relieve pressure before removing caps, plugs, covers or other parts from pressurized air system. • Open service valve at end of machine. •...
Operating & Maintenance Manual MAINTENANCE Scavenge Line WARNING High pressure air can cause severe injury or death from hot oil and flying parts. Always relieve pressure before removing caps, plugs, covers or other parts from pressurized air system. The scavenge line originates at the manifold and terminates at the compressor airend near the oil filter element.
Page 53
MAINTENANCE Operating & Maintenance Manual Field Repair of Texture Paint 1. The sheet metal should be washed and clean of foreign material and then thoroughly dried. 2. Clean and remove all grease and wax from the area to be painted using Duponts 3900S Cleaner prior to sanding.
Operating & Maintenance Manual Troubleshooting Troubleshooting B. Do The Simplest Things First Most troubles are simple and easily corrected. For example, most complaints are Introduction “low capacity” which may be caused by too low an engine speed or “compressor over- Troubleshooting for a portable air heats”...
Troubleshooting Operating & Maintenance Manual Trouble Shooting Chart Bold Headings depict the COMPLAINT - Subheadings indicate CAUSES NOTE: Subheadings suggest sequence to follow troubleshooting. Table 1: Machine Shutdown Cause Corrective Action Out of fuel Add CLEAN diesel fuel. Low fuel shutdown (option) Add CLEAN diesel fuel.
Page 58
Operating & Maintenance Manual Troubleshooting Table 3: Machine Will Not Run Cause Corrective Action Out of fuel Add clean diesel fuel. Low fuel shutdown (option) Add clean diesel fuel. See table 11. Airend discharge temperature too high See table 4. Separator temperature to high See table 5.
Page 59
Troubleshooting Operating & Maintenance Manual Table 5: High Separator Temperature Shutdown SECU CODE 2 Cause Corrective Action Dirty cooler Clean cooler. Low compressor oil level Add oil. Check for leaks. Clogged compressor oil filter elements Replace elements. Change oil. Operating pressure too high Reduce pressure setting to within spec.
Page 60
Operating & Maintenance Manual Troubleshooting Table 7: High Engine Coolant Temperature Shutdown SECU CODE 4 Cause Corrective Action Dirty cooler Clean cooler. Dirty operating conditions Relocate machine to cleaner environment. Machine out of level>15 degrees Relocate or level machine. Ambient temperature>120°F (49°C) Above spec.
Page 62
Operating & Maintenance Manual Troubleshooting Table 16: Generator Switch on SECU CODE H (Electronic Engine Models Only) Cause Corrective Action Machine will not start Switch generator to the air only position. Generator switch malfunction Check harness connections. Replace switch. SECU controller malfunction Check harness connections.
Page 63
Troubleshooting Operating & Maintenance Manual Table 21: Oil Seal Leak Cause Corrective Action Contaminated Lube Oil Drain and flush system. Add new CLEAN oil. Replace seal. Malfunctioning Seal Consult dealer. Replace seal. Scored Shaft See instructions in new seal kit. Table 22: Will Not Unload Cause Corrective Action...
Need help?
Do you have a question about the P185WYM-T4I and is the answer not in the manual?
Questions and answers