Download Print this page

Kinetico 2030s Installation Instructions page 2

Advertisement

INSTALLATION INSTRUCTIONS
2.
Install with by-pass valving as shown in Figure 1. Note the inlet and outlet arrows on valve head.
3.
Connect the inlet/outlet adapters leading to the conditioner using 1½", 1¼", 1" or ¾" plumbing. Plumb as
necessary to accommodate a by-pass valve and to complete the installation. Solder adapters to pipe (if
applicable). Glue if P.V.C.
Caution: Do not solder brass adapters while they are inserted in the control module. Damage to the
plastic and rubber parts may result due to the heat. Also, the materials used in the soldering
process may attack certain types of plastics. Take care during the installation process to
assure that solder and flux do not come in contact with media tanks, the control module, E-
clips and related plastic components.
NOTE:
Kinetico strongly recommends installing a vacuum breaker in the outlet line to insure there
will not be negative pressure.
4.
After all plumbing is completed, but before connecting equipment, flush both the inlet and outlet lines by
opening the by-pass valve and allowing water to rinse out any debris in the lines.
5.
Locate the enclosed kit containing four O-rings, two pipes with O-rings and a silicone packet. Apply a liberal
amount of silicone to the four O-rings and the O-rings on the two pipes. Install the four O-rings on the
inlet/outlet adapters.
6.
Use the adapter bracket and clevis pins to connect adapters to 1" control valves. See Figure 2. For 1¼" valve,
press in E-clips until they securely snap in place.
NOTE: Step 7 is unnecessary for 2040C.
7.
Connect the remote tank to the main tank using connector pipes, connector links
and connector pins. See Figure 2 (always use both links).
NOTE: Provide an air gap for all drain lines. Check local and state plumbing
codes for the proper setup of drain line air gaps.
Air Gap Instructions. Provide an air gap for all drain lines. Waste
connections or drain outlets shall be designed and constructed to provide for
connection to the sanitary waste system through an air gap of 2 pipe diameters
or 1" (25 mm), whichever is larger.
8.
Run a drain line to a discharge point. FOLLOW STATE AND LOCAL CODES.
Before connecting unit, check for any obstructions or kinks. Apply Teflon tape to
the pipe threads on the side of the softener valve, and install the two fittings
supplied. Remove the nut from the drain fitting. (Slide nut on first, then split gripper with flat surfaces away
from the nut. Lastly, slide the hat sleeve with the larger diameter side toward the nut.) The end of the drain line
should extend about ½" from the end of hat sleeve. Slide into elbow as far as it will go, and hand-tighten nut
firmly and then wrench tighten 1 ½ to 2 turns.
NOTE: On drain lines that must travel more than 8 feet up and 30 feet over, it is best to take the ½" drain
line that fits the valve and attach it to a larger diameter line or pipe.
9.
Position the brine drum. Remove brine valve and adjust salt setting for the water hardness and meter disc
being used. Replace the brine valve and attach the ⅜" brine line from the module to the brine valve. Hand-
tighten fittings and then wrench tighten 1 ½ to 2 turns.
10. Add a clean grade of salt at this time. DO NOT USE ROCK SALT.
Rev. 06/2011
Kinetico Incorporated ♦ Corporate Headquarters ♦ Newbury, Ohio 44065 ♦ 440-564-9111
Kinetico 2030s, 2040s OD, 2050s, 2060s,
2100s, 2100s OD, 4040s OD, 2060s OD, 2030f OD
2060f OD, 2100f OD Backwashing Filters
2040C, 4050s 4060s OD Macrolite
4060s OD Activated Carbon, 4060f OD,
2080f OD Greensand, 2060s Tannin Plus
2
®
®
®
AquaKinetic
Q237
Product No. 11013M
,

Advertisement

loading

This manual is also suitable for:

2040s od2050s2060s2100s2100s od4040s od ... Show all