Fostex CR300 Service Manual page 16

Compact disc recorder
Hide thumbs Also See for CR300:
Table of Contents

Advertisement

CR300
3-5. ADJUSTMENT 2 (SERVO SYSTEM ADJUSTMENT)
For servo adjustment, set the INPUT SELECTOR to OPTICAL.
Use the RECORD and REC MUTE buttons to make the adjustments.
To register an adjustment, press the (SKIP ID) SET button.
To reset the adjusted values to the initial settings, press and hold the
(SKIP ID) CLEAR button for 4 seconds.
3-5-1. Focus Offset Adjustment
Test Point
Adjustment Point
Adjustment Value
[Procedure]
(1)
Press the AUTO/MANUAL button until "01_F4" appears on the FL display.
(2)
Adjust with the RECORD and REC MUTE buttons until the value for Pin 6 of CN354 is 0 mV ± 10 mV.
(3)
Press the SET button to register the adjustment. Once the adjustment is registered with the SET button, "?" will
disappear.
16
INPUT SELECTOR
DIGIT AL
ANALOG
XLR / +4
COAX
XLR / -10
OPT
LINE
AES /
EBU
REC
RECORD
MUTE
SKIP ID
SET
CLEAR
CN354 - pin 6 (FE)
RECORD and REC MUTE buttons
0 mW ± 10 mW
FE
10 : 1
VC
10:1 probe
Oscilloscope
SERVO DIGITAL ASSY
CN354 (TP201)
1
6
CN354
1 : RF
CN102
2 : TE
1
3 : TEIN
4 : VC
6
5 : FEIN
6 : FE
CN102
1 : VC
2 : TESTEQRFP
3 : TE
4 : MPP
5 : MPXOUT
6 : FMOUT
Fig. 6 Adjustment points