8.
Precautions when using the fixture
Warning! Never use the fixture without a lamp or reflector!
Warning! Always wait 20 - 30 minutes for the emitter cover/reflector to cool down!
9.
Troubleshoot using the status LED
Note: The status LED is present at 1000 W models only.
The status LED provides information on the condition of the lamp and electronic ballast.
Consult table 1 to interpret the status LED. LED signals are represented by colored red dots.
9.1.

Status indications

Status LED message








Table 1
Legend
LED message


Status fixture
Description
No error
The lamp is working correctly
Maximum number of ignition attempts
EOL timer expired
done without succes or a driver is
locked or has failed
Maximum number of succesful ignition
Cycle error
attempts done (lamp stopped for
unknown reason)
Low mains
Mains voltage too low
Maximum driver temperature
Thermal overload
exceeded
Lamp voltage out
Lamp voltage too low, lamp voltage too
of range
high or DC shift detected
Mains voltage too high and/or DC-bus
High mains
voltage too high
Ignition busy
Ballast is trying to ignite the lamp
Time (approx.)
256 ms.
512 ms.
Action/Solution
-
Reset mains cycle manually
Reset mains cycle manually
Mains cycle automatically resets
Reset mains cycle manually
No action required.
Mains cycle automatically resets
-