No.
Part name
2. Reactor
Exchange of
5
electric parts
1) Carry out works of 1 of
(Continued)
2) Remove the relay connector connected to
3) Remove each reactor.
4) Attach a new reactor.
Procedure
1
the control P .C. board.
(Truss B tight screw Ø4 × 6, 2 pcs. each)
and
3
.
- 68 -
FILE NO. SVM-17005
Remarks
Reactor relay connector
(Connected to lead wire
(White) at P.C. board side)
Screws