2.1.5 Response data (Characteristics UUID: 0x3005)

Retrieved memory data in the page and row specified in 2.1.3 Request page will be updated in this
characteristic. Correct data acquisition can be made after the update flag becomes "Completed" in
2.1.5 Response flag. Also, by reading this Characteristic, the data of the next row in the same page
is automatically set to this Characteristic (descending order Row 12 to Row 0).
Therefore, it is unnecessary to specify 2.1.3 Request page for each row, and all row in the same
page can be read by continuous Read of this Characteristic. However, since automatic retrieving
across pages is not performed, when moving to the next page, it is necessary to specify the page
number again to 2.1.3 Request page and confirm the 2.1.4 Response flag each time.
* Note: Memory recording of measured data is not started unless 2.3.1 Time information is set.
Byte
0
Row number
1
Temperature
2
3
Relative Humidity
4
5
Light
6
7
UV Index
8
9
Barometric Pressure
10
11
Sound noise
12
13
Discomfort Index
14
15
Heatstroke risk factor
16
17
Supply voltage
18
2JCIE-BL01-P1 Environment Sensor (PCB Type) User's Manual (A280)
Table 12. Response data format
Field
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
Format
UInt8
Range:0~12
SInt16
Unit:0.01 degC
SInt16
Unit:0.01 %RH
SInt16
Unit:1 lx
SInt16
Unit:0.01
SInt16
Unit:0.1 hPa
SInt16
Unit:0.01 dB
SInt16
Unit:0.01
SInt16
Unit:0.01 degC
UInt16
Unit:1 mV