Operation - Campbell Hausfeld FP2051 Operating Instructions And Parts Manual

Campbell hausfeld operating instructions portable air compressor fp2051, fp2052
Table of Contents

Advertisement

Compresor de aire portátil
Para Ordenar Repuestos Sírvase Llamar al Distribuidor Más Cercano a su Domicilio
Sírvase darnos la siguiente información:
-Número del modelo
-Número de Serie (de haberlo)
-Descripción y número del repuesto según la lista de repuestos
23
6
15
4
37
29
35
36
11
43
34
20
21
33
19
32
9
31
16
25
27
27
10
7
2
13
Puede escribirnos a:
Campbell Hausfeld / Attn: Parts Department
100 Production Drive
Harrison, OH 45030 U.S.A.
42
41
47
8
17
1
38
19
21
20
18
48
50
49
51
3
5
40
28
39
52
53
14
46
45
24
12
30
44
54
FP2051, FP2052
26 Sp
Installation
(Continued)
DANGER
!
Do not use a
grounding adapter with this product!
Tank gauge
2. If repair or replacement of cord or plug
is necessary, do not connect grounding
wire to either flat blade terminal. The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding wire.
Outlet
gauge
Never connect
WARNING
!
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
Figure 2 - Unit Identification
plug provided; if it will not fit outlet,
have proper outlet installed by a
Use the screws provided to attach the
qualified electrician.
bracket to the wall. Make sure to
mount to the wood stud, not just to
Overheating, short
CAUTION
!
drywall.
circuiting and fire
damage will result from inadequate
For mounting to a concrete surface,
wiring, etc.
pre-drill holes in the concrete and insert
WALL MOUNTING
the anchors that are provided. Align
the holes in the bracket with the wall
This compressor can be mounted to the
anchors and use the three screws
wall for convenient storage. It can also
provided to attach the bracket to the
be operated while in the hanging
wall.
position.
Avoid mounting compressor to drywall
Before mounting, select a location at a
or gypsum board unless screws are
wall stud or on a concrete surface.
lagged into wood studs.
Make sure that the mounting area
Mounting air compressor to bracket
measures at least 24" x 30".
There are three mounting hooks on the
Hang compressor on
WARNING
!
a properly installed
wall hanging bracket. On the back of
hanger sturdy enough to support
the compressor shroud, there is an
compressor's weight (approximately 25
opening that serves as a handle. The
pounds). Do not hang on peg board,
two hooks on the top of the bracket fit
wallboard, or any structure not suited
in the handle opening on the
to hold compressor's weight.
compressor shroud. The remaining
Mounting hanger bracket
hook on the bottom of the bracket fits
For mounting to a wood stud, the
into the lower part of the compressor
bracket has three holes in the center.
shroud, below the handle opening.
These holes are located in between the
two mounting hooks that attach to the
HOSE STORAGE
back of the compressor. Use a stud
1. Attach one of the threaded ends of
finder to locate the center of the stud.
recoil hose to air outlet on front of
Extension cords for 120V/2.5 Amp Unit
Length of Cord (ft)
25
50
100
Gauge of Cord
18
18
16
FP2051, FP2052
Safety valve
On/off switch
Regulator
compressor.
2. Route recoil hose to side of tank
where hose strap is located.
3. Loosen lower end of hose strap.
4. Slide as much of recoil as possible
onto hose strap.
5. Reattach hose strap to compressor.

Operation

Definition of Terms
Regulator - The regulator controls the
amount of air pressure released at the
hose outlet.
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Handle - Designed to move the
compressor.
Drain Valve - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.
Reduce tank pressure below 10 psi,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
150
200
250
300
400
14
14
12
12
10
www.chpower.com
3
500
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp2052

Table of Contents