Download Print this page

Available Functions - ABB REC670 Product Manual

Relion 670 series, pre-configured
Hide thumbs Also See for REC670:

Advertisement

Bay control REC670
Pre-configured
Product version: 1.1

2. Available functions

ANSI
Function description
Control
25
Synchrocheck, energizing check and synchronizing
(SESRSYN)
79
Autorecloser (SMBRREC)
Apparatus control for single bay, max 8 apparatuses
incl. interlocking (APC8)
Apparatus control for single bay, max 15 apparatuses
incl. interlocking (APC15)
Apparatus control for single bay, max 30 apparatuses
incl. interlocking (APC30)
90
Automatic voltage control for tapchanger, single
control (TR1ATCC)
90
Automatic voltage control for tapchanger, parallell
control (TR8ATCC)
84
Tap changer control and supervision, 6 binary inputs
(TCMYLTC)
84
Tap changer control and supervision, 32 binary
inputs (TCMYLTC)
Logic Rotating Switch for function selection and
LHMI presentation (SLGGIO)
Selector mini switch (VSGGIO)
Differential protection
87
1 phase High impedance differential protection
(HZPDIF)
Current protection
50
Instantaneous phase overcurrent protection (PHPIOC)
51/67
Four step phase overcurrent protection (OC4PTOC)
50N
Instantaneous residual overcurrent protection
(EFPIOC)
51N/
Four step residual overcurrent protection (EF4PTOC)
67N
46I2
Four step directional negative phase sequence
overcurrent protection (NS4PTOC)
67N
Sensitive directional residual overcurrent and power
protection (SDEPSDE)
26
Thermal overload protection one time constant
(LPTTR)
49
Thermal overload protection two time constants
(TRPTTR)
50BF
Breaker failure protection (CCRBRF)
52PD
Pole-discordance protection (CCRPLD)
37
Directional underpower protection (GUPPDUP)
32
Directional overpower protection (GOPPDOP)
46
Broken conductor check (BRCPTOC)
Voltage protection
27
Two step undervoltage protection (UV2PTUV)
4
1MRK 511 192-BEN B
Single Breaker
Double brekaer
(A30)
(B30)
Basic
Option
Basic
Option
(Qty/
(Qty/
Option
Option
design)
design)
1
2
-
1/H04
-
2/H05
1
-
-
-
-
-
1
-
-
-
-
-
-
1/H11
-
1/H11
-
1/H15
-
1/H15
4
-
4
-
4
-
4
-
15
-
15
-
20
-
20
-
-
3/A02
-
3/A02
-
1/C21
-
2/C22
-
1/C21
-
2/C22
-
1/C31
-
2/C32
-
1/C31
-
2/C32
-
1/C31
-
2/C32
-
1/C16
-
1/C16
-
1/C31
-
1/C32
-
1/C31
-
1/C32
-
1/C31
-
2/C32
1
-
2
-
-
1/C17
-
1/C17
-
1/C17
-
1/C17
1
-
1
-
-
2/D02
-
2/D02
Issued: June 2010
1 1/2 breaker for
individual CB
(C30)
Basic
Option
(Qty/
Option
design)
3
-
3/H06
-
-
-
-
1
-
-
2/H16
-
2/H18
4
-
4
-
15
-
20
-
-
6/A07
-
2/C23
-
2/C23
-
2/C33
-
2/C33
-
2/C33
-
1/C16
-
2/C33
-
2/C33
-
3/C33
3
-
-
1/C17
-
1/C17
1
-
-
2/D02
ABB

Advertisement

loading