11.2 Power consumption temperature curves
indoor temp.
DB/WB
15
18/12
837
845
21/15
916
24/16
27/19
947
30/22
973
968
32/23
1500
1300
1100
900
700
500
300
100
AS35NC1HRA 1U35QE3ERA performance curves
power consumption value-temp.table
10
0
10
847
837
823
871
867
832
936
918
897
968
947
926
1000
988
956
995
970
975
power consumption-temp.curves
indoor tempe.(DB/WB)
20
25
396
571
423
585
453
643
465
656
497
695
506
717
54
Capacity
30
35
40
736
901
1020
738
935
1073
813
982
1148
839
1000
1181
901
1111
1232
917
1135
1315
15
10
0
10
20
25
30
35
40
46
Domestic Air Conditioner
46
1092
1129
1230
1263
1330
1372