Panasonic WH-SXC09H3E8 Service Manual page 65

Air-to-water
Table of Contents

Advertisement

Screws
11.1.5.2
Fixing of Power Supply Cord
and Connecting Cable
1. Connecting cable between Indoor Unit and
Outdoor Unit shall be approved polychloroprene
sheathed 4 × 1.5 mm
designation 60245 IEC 57 or heavier cord.
Ensure the colour of wires of Outdoor Unit and
the terminal no. are the same to the Indoor
Unit respectively.
Earth wire shall be longer than other wires as
shown in the figure for the electrical safety in
case of the slipping out of the cord from the
Holder (Clamper).
2. An isolating device must be connected to the
power supply cable.
Isolating device (disconnecting means) should
have minimum 3.0 mm contact gap.
Connect the approved polychloroprene
sheathed power supply 1 cord and power
supply 2 cord and type designation 60245 IEC
57 or heavier cord to the terminal board, and
to the other end of the cord to isolating device
(Disconnecting means). See below table for
cable size requirement.
For model S*C09*3E8
Power Supply
Cable Size
Cord
5 × minimum
1
1.5 mm
2
3 × minimum
2
1.5 mm
2
For model S*C12/16*9E8
Power Supply
Cable Size
Cord
5 × minimum
1
2
1.5 mm
5 × minimum
2
2
1.5 mm
3. To avoid the cable and cord being damaged by
sharp edges, the cable and cord must be passed
through a bushing (located at the bottom of
Control Board) before terminal board. The bushing
must be used and must not be removed.
Screws
2
flexible cord, type
Isolating
Recommended
Devices
RCD
20A
30mA, 4P, type A
15/16A
30mA, 2P, type AC
Isolating
Recommended
Devices
RCD
20A
30mA, 4P, type A
20A
30mA, 4P, type AC
For model S*C09*3E8
Terminal on the outdoor unit
Colour of wires (Connecting cables)
Terminal on the indoor unit
(Power Supply Cord)
Terminals on the isolating device
from power supply (Disconnecting
means)
For model S*C12/16*9E8
Terminal on the outdoor unit
Colour of wires (Connecting cables)
Terminal on the indoor unit
(Power Supply Cord)
Terminals on the isolating device
from power supply (Disconnecting
means)
RCCB/ELCB
*1
Power Supply Cord
Terminal screw
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
11.1.5.3
Wire Stripping and Connecting
Requirement
Wire stripping
No loose strand
when insert
Conductor
fully insert
ACCEPT
65
Main Power Supply
1
or Main + Backup
Booster Heater
Heater Power Supply
Power Supply
L
L
L
N
L
N
1
A1
A2
A3
Indoor unit/Outdoor unit
L
L
L
N
L
N
A1
A2
A3
Power Supply 1
Power Supply 2
1
Booster + Backup
Main Power Supply
Heater Power Supply
1
L
L
L
N
L
L
L
N
A1
A2
A3
B1
B2
B3
L
L
L
N
L
L
L
N
A1
A2
A3
B1
B2
B3
Power Supply 1
Power Supply 2
Holder
(Clamper)
Connecting Cable
Tightening torque cN•m {kgf•cm}
157~196 {16~20}
196~245 {20~25}
Indoor/outdoor
connecting
terminal board
5mm or
more
(gap between
wires)
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED
2
3
4
5
2
3
4
5
connection
2
3
4
5
2
3
4
5
Indoor un it/Outdoor un it
connect ion
Terminal Board
*1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-sxc12h9e8Wh-sxc16h9e8Wh-ux09he8Wh-ux12he8Wh-ux16he8

Table of Contents