Panasonic WH-SXC09H3E8 Service Manual page 18

Air-to-water
Table of Contents

Advertisement

1
Display
1
Mode selection
AUTO
• Depending on the preset outdoor
temperature, the system selects
HEAT or *
AUTO
• Depending on the preset outdoor
+ TANK
temperature, the system selects
HEAT + TANK or *
operation mode.
HEAT
• The panel/floor HEAT operation is
either turned ON or OFF.
• The outdoor unit provides heat to
the system.
HEAT
• The outdoor unit provides heat to
+ TANK
the water tank and the system.
• This mode can be selected only
when the water tank is installed.
Operation icons
2
The status of operation is displayed.
Icon will not display (under operation OFF screen) whenever operation is OFF except weekly timer.
Holiday operation status
Zone:Room Thermostat
→Internal sensor status
Room Heater status
Bivalent status
(Boiler)
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
3
Temperature of each zone
4
Time and day
5
Water Tank temperature
6
Outdoor temperature
7
Sensor type/Set temperature type icons
Water Temperature
→Compensation curve
Room Thermostat
→External
2
1
23
44
˚ c
7
1
COOL operation mode.
Auto Heat
Auto Cool
1
COOL + TANK
Auto Heat
Auto Cool
Weekly Timer operation status
Powerful operation status
Tank Heater status
Water Temperature
→Direct
Room Thermostat
→Internal
18
3
4
10:34am, Mon
2
40
˚ c
˚ c
18
˚ c
*
*
COOL
• The fan coil unit is either turned
1,
2
ON or OFF.
• The outdoor unit provides cooling
to the system.
*
1,
*
2
COOL
• The outdoor unit provides cooling
to the system.
+ TANK
• The system controls the booster
heater in the water tank.
TANK
• The water tank is either turned
ON or OFF.
• The outdoor unit provides heat to
the water tank.
* The direction icons point to the currently
active mode.
• Room operation / Tank operation.
• Deice operation.
Quiet operation status
Demand Control or
SG ready or SHP status
Solar status
Pool only
5
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-sxc12h9e8Wh-sxc16h9e8Wh-ux09he8Wh-ux12he8Wh-ux16he8

Table of Contents