Hood sensor

The hood sensor is attached to the rear of the chassis.
1.
Prepare the computer for disassembly
2.
Remove the access panel
3.
Remove the air duct
4.
Disconnect the hood sensor cable from the system board connector labeled HSENSE (1).
5.
Slide the hood sensor out of the slot on the rear of the chassis (2). A tool such as a screwdriver may be
required to disengage the hood sensor from the slot.
To install the hood sensor, reverse the removal procedure.