16 |
Mounting
Supplier
Method
2-E-1
2-E-2
Powerway
Renewable Energy
Co.,Ltd
2-E-3
2-E-4
2-F-1
2-F-2
Akcome Metals
Technology
(Suzhou) Co.,Ltd.
2-F-3
2-F-4
The following clamps in table 3 have been approved
as compatible with Canadian Solar double glass
module CS6X-P-FG and CS6X-M-FG.
EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
Clamp Image
Clamp Type & length
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=100 mm
PW-CS-01 (End clamp) /
PW-CS-02 (Middle clamp),
clamp length=200 mm
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=80 mm
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=100 mm
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=100 mm
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=200 mm
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=80 mm
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=100 mm
Clamp Quantity &
Load (Pa)
Location
four clamps,
Downforce load≤2400 Pa
A=380±20 mm,
Uplift load ≤2400 Pa
see illustration A
four clamps,
Downforce load≤5400 Pa
A=380±20 mm,
Uplift load ≤2400 Pa
see illustration A
six clamps,
A=250±20 mm,
Downforce load≤2400 Pa
B=579±20 mm,
Uplift load ≤2400 Pa
see illustration B
six clamps,
A=250±20 mm,
Downforce load≤5400 Pa
B=579±20 smm,
Uplift load ≤2400 Pa
see illustration B
four clamps,
Downforce load≤2400 Pa
A=380±20 mm,
Uplift load ≤2400 Pa
see illustration A
four clamps,
Downforce load≤5400 Pa
A=380±20 mm,
Uplift load ≤2400 Pa
see illustration A
six clamps,
A=250±20 mm,
Downforce load≤2400 Pa
B=579±20 mm,
Uplift load ≤2400 Pa
see illustration B
six clamps,
A=250±20 mm,
Downforce load≤5400 Pa
B=579±20 mm,
Uplift load ≤2400 Pa
see illustration B
Certification
Body
VDE / CSA
VDE / CSA
VDE / CSA
VDE / CSA
VDE/CSA
VDE/CSA
VDE / CSA
VDE / CSA

Advertisement

Table of Contents
loading

Table of Contents