List of parameters and Factory stored programs
Factory Configuration
Function
Preflow
Starting Current
Initial slope
Operating
Amperage
Final Slope
Finishing Current
Post flow
Percent of Peak
Current / Duty
Cycle
(Only when pulse
function is enabled)
Pulses-Per-Second
DC
(Only when pulse
function is enabled)
Pulses-Per-Second
AC
(Only when pulse
function is enabled)
Background
Current
(Only when pulse
function is enabled)
SPOT time
(Only when spot
function is enabled)
Low level
background
(Only when Bilevel
function is enabled)
Factory Configuration
Function
EN Offset
EP Offset
AC-Balance
AC-Frequency
English
Selectable Value
Default
.5
0 - 25s (step 0.1s)
100
10 – 200 % (step 1%)
0.1
0 – 5s (step 0.1s)
2 – 300 A (step 1A)
50
5 – 270 A (step 1A)
0
0 - 25s (step 0.1s)
30
10 – 90 % (step 1%)
0.1 - 60s (step 0.1s)
AUTO
5-95 (step 5%)
40
0,1 – 10 Hz (step
0.1
10 – 500Hz (step 1Hz)
500 – 2000Hz (step
0,1 – 10 Hz (step
0.1
10 – 100Hz (step 1Hz)
25
10 -90 % (step 1%)
0 – 10s (step 0.1s)
0
10 – 100s (step 1s)
25
10 -90 % (step 1%)
AC Wave Balance
Selectable Value
Default
AUTO
2 – 300A (step 1A)
AUTO
2 – 300A (step 1A)
AUTO
35 – 95 % (step 1%)
120
40 – 400Hz (step 1Hz)
Displayed
Range
parameter name
PRE
STRT
UP
(TIG)
(Stick)
DOWN
END
POST
Note A
PEAK
Note B
0.1Hz)
FREQ
10Hz)
0.1Hz)
FREQ
Note C
BACK
SPT
A2
Displayed
Range
parameter name
EN
EP
%BAL
FREQ
18
Displayed value
Current selected value
(s)
Current selected value
(%)
Current selected value
(s)
Current selected value
(A)
Current selected value
(s)
Current selected value
(%)
Current selected value
(s)
% of FREQ
Current selected value
(Hz)
Current selected value
(Hz)
Current selected value
(%)
Current selected value
(s)
Current selected value
(%)
Displayed value
Current selected value
(A)
Current selected value
(A)
Current selected value
(%)
Current selected value
(Hz)
English