2-2-2. Outdoor Unit
Outdoor Unit
SAP – CM1822A
Type
Compressor model ... Number
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Type
Overload relay ... Number
Safety
devices
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor ... Number
Type
Number ... Dia.
Fan motor model ... Number
No. of poles ... rpm (240 V)
Nominal output
Coil resistance (Ambient temp. 20°C)
Type
Safety
devices
Operating temp.
Run capacitor
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
External protector (OLR 1, 3)
Open
°C
Close
°C
Trip in 6 to 16 sec. at 16A
µF
VAC
mm
W
Open
°C
Close
µF
VAC
mm
m 2
4
Rotary (Hermetic)
C – 1R80H5K ... 2 / 80603345 – S ... 2
4GS D –T or SAY-56T ... 320 × 2
C – R : 3.65
C – S : 5.38
MRA99109-9201 ... 2
150 ± 5
69 ± 11
30.0 ... 2
400 ... 2
Propeller
1 ... ø420
KFG6 – 51C5P – S ... 1
6 ... 880
WHT – BRN : 67.1
WHT – YEL : 83.8
Thermal protector
130 ± 8
Automatic reclosing
Aluminum plate fin / Copper tube
0.506
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
800
External protector (OLR 2, 4)
CS-7C115 ... 2
115 ± 3
95 ± 5
50
4.0
440
1