Outdoor Unit
AVOID:
heat sources, exhaust fans, etc. (Fig. 3)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air
intake/exhaust and possible maintenance.
(Figs. 4a and 4b)
provide a solid base (concrete block, 10
beams or equal), a minimum of 10 cm above ground
level to reduce humidity and protect the unit against
possible water damage and decreased service life.
(Fig. 5)
use lug bolts or equal to bolt down unit, reducing vibra-
tion and noise.
Required space around the unit.
Air intake
Min. 10 cm
Min.
Min.
Air discharge
5 cm
40 cm
Top View
Fig. 4a
Top View
Air intake
Concrete
or equal
Outdoor unit
40 cm
Valve
side
Min. 25 cm
Fig. 5
Fig. 5 - A
16
Hot air
Fig. 3
Fig 3
Obstacle above
2 m
2 m
Ground
Side View
Fig. 4b
Fig. 4 - C
Anchor bolts
(4 pcs.)
Min. 10 cm
Exhaust fan
Heat source