6-3 OTHER ELECTRIC COMPONENTS
No Cooling
Compressor
doesn´t run.
Running state of
Compressor is poor.
Fan Motor doesn´t
run.
Much frost is on the
evaporator.
Check if current flows to
the following components.
a. Starting Devices
b. OLP
c. Compressor coil
d. Circuit Parts
Check starting
voltage.
Check if current
flows to starting
devices.
Check current
flowing in sub-coil
of Compressor.
Check capacity of
OLP.
The items
described above
are normal.
Checker current
flow of the door
switch.
Check current
flowing in the fan
motor.
Check current flow
of the following
components:
·
Defrost Control
Check current flow
of the following
components:
·
L-CORD, TE-PLATE
Cause
Shorted or Broken
Poor contact or shorted.
Coil Shorted.
Poor contact or shorted.
Low Voltage
Poor contacting
and broken.
Shorted
Lack of Capacity
Compressor
Motor Coil.
Poor contact
Coil is shorted
Shorted
18
Replace each
component.
Raise the voltage.
Replace the
defective
component.
Replace the
Compressor.
Replace the
defective
component.
Replace PTC.
Replace PTC.