AXIS P3346-VE Fixed Dome Network Camera
Technical Specifications

Connectors

I/O Connector
4-pin terminal block for:
• Auxiliary power (DC output)
• Digital Input
• Digital Output
• 0 V DC (-)
Function
0 V DC (-)
DC output
Digital Input
Digital Output
Audio Connector
3.5 mm audio connectors
(stereo)
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate
4
Connected to pin 1 when activated, floating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
3.3 V max 50 mA
1
1
2
3
4
3
2
1
64
Specifications
0 V DC
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open drain,
100 mA