Instruction Manual Weather Center model 01605 heat ind ex wind chill ew point WIND average peak current auto manual 12-24 hour forecast barometer Learning... high indoor humidity! h igh high low i n door h r umidity! AUTO DST O N O FF...
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective flm that is applied to the LCD screen prior to using this product.
Features & Benefits 3-in-1 SENSOR 5. Mounting Hardware Includes anchors and screws. 1. Temperature & Humidity Sensors Diameter Length (internal) 1” 2. Release Lever for Battery Access #6 or #8 1/4” or 3/8” 3. Mounting Point 6. Mounting Bracket 4. Wind Speed Anemometer 7.
Features & Benefits heat index wind chill ew point WIND average peak current auto manual 12-24 hour forecast barometer Learning... high indoor humidity! high high low indoor h r umidity! AUTO DST ONOFF TIME ZONE AUTO DIM DISPLAY UNIT 1. Current Outdoor Temperature 10.
Page 5
Features & Benefits BACK OF DISPLAY UNIT 5. Battery Compartment 6. Plug-in for Power Adapter Button for setup preferences. 7. A-B-C Switch ID code that must match sensor’s A-B-C Button switch to ensure units synchronize. for setup preferences. 8. Reset Button Button Full reset to factory defaults.
SETUP 3-IN-1 Sensor Setup Set the A-B-C Switch 1. Press the release lever and pull off the lower housing of the The A-B-C switch is located inside sensor. the battery compartment. It can be 2. Remove the battery compartment set to A, B or C. However, you must cover.
Display Unit Setup Set the A-B-C Switch 2. Insert 3 x AAA alkaline batteries into the battery Locate the A-B-C switch inside compartment, as shown. the battery compartment. Set Follow the polarity (+/–) the A-B-C switch to A, B or C. diagram in the battery You must select the same letter compartment.
Set the Time, Date & Units Press the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display. To adjust the currently selected (flashing) item, press and release the “ “ or “...
Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product. Display Unit Placement heat index wind chill ew point WIND Place the display unit in a dry area free of dirt and dust.
3-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to fence post, 2”x4” wood, 3/4” pole, etc. (not included) LEVEL INSTALLATION Use a bubble level (not included) to ensure level installation for accurate wind measurement.
OPERATION Using The Weather Center Learning Mode Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.
Page 12
High & Low Records Today’s high and low records are displayed for indoor and outdoor temperature, humidity and wind speed. Today’s records automatically clear at 12:00am midnight every day. To manually clear all of today’s LOW recorded values, press and hold the “...
Troubleshooting Problem Possible Solution • Relocate the display unit and/or the 3-in-1 sensor. The units must be within 330 ft (100 m) of each other. • Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
Page 14
Troubleshooting Problem Possible Solution • Make sure both the display unit and 3-in-1 sensor are placed away from any heat sources or vents (see page 9). • Make sure both units are positioned away from moisture Inaccurate sources (see page 9). temperature or •...
Care & Maintenance Display Unit Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. 3-in-1 Sensor Care Clean the Sensor Clean with a soft, damp cloth.
*To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the “ ” button for at least 10 seconds. The display indicates the current pressure mode selected,“AUTO” or “MANUAL”. After 20 seconds of inactivity, the display will save the adjustments and exit calibration mode.
Specifications Outdoor: -40ºF to 158ºF; -40ºC to 70ºC TEMPERATURE RANGE Indoor: 32ºF to 122ºF; 0ºC to 50ºC Outdoor: 1% to 99% HUMIDITY RANGE Indoor: 1% to 99% 0 to 99 mph; 0 to 159 kph WIND SPEED 330 ft / 100 m depending on home construction materials WIRELESS RANGE 433 mhz OPERATING FREQUENCY...
Customer Support AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 info@chaney-inst.com AcuRite 24/7 support at www. .com Installation Videos Register your Product...