Electrical Information

A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110/120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to unswitched 110/120
VAC. This is required for proper operation of the
appliance.
• A 110/120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
NOTICE: Waterproof insulated wire should be used when
wiring the junction box.
Outdoor Lifestyles by Hearth & Home Technologies • TWILIGHT-II-MDC Installation Manual • 2369-970 Rev. L • 8/19
Junction Box Installation
If the box is being wired from the OUTSIDE of the appliance:
• Install the Romex™ connector (not included with
appliance) in the side wrap.
• Loosen two screws on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections.
If the box is being wired from the INSIDE of the appliance:
• Remove the screw attaching the junction box to the
outer shell, rotate the junction box inward to disengage
it from the outer shell (see Figure 6.1).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections to the receptacle
and assemble the receptacle and cover to the junction
box.
HEAT SHIELD
BLK
WHT
BLK
WHT
Figure 6.1 Junction Box Detail
14/2WG
COPPER GROUND
ATTACHED TO GRN SCREW
WITH GRN WIRE
GREEN WIRE
INSIDE BOX
NOTE: Do NOT wire
110 VAC to wall switch.