B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls. See Figure
3.2.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
C*
Millimeters
Figure 3.2 Appliance Locations
10
Outdoor Lifestyles by Hearth & Home Technologies • TWILIGHT-II-MDC Installation Manual • 2369-970 Rev. L • 8/19
GLASS
B
NOTE: Appliance may be installed flush on exterior, interior
or anywhere in between. Any projection of the appliance
interior or exterior must have a properly constructed chase
surrounding the appliance. The exterior must have proper
insulating, flashing and finishing to ensure an insulated
envelope.
WARNING! Risk of Fire! The exterior side of the TWILIGHT-II-MDC
CANNOT be recessed into the framing.
D
GLASS
C* = 24 INCH (MAX.)
GLASS
A
B
Minimum Minimum Minimum
Inches
43
1/2
1092
13
* = C dimension may be any length from 0 to 24 inches.
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
WARNING!
TWILIGHT-II-MDC CANNOT be recessed into the
framing.
GLASS
B
A
E
B
FLUSH TO EXTERIOR INSULATED ENVELOPE
C*
Maximum
0
24
0
610
Risk of Fire! The exterior side of the
EXTERIOR INSULATED ENVELOPE
C* = 0 INCH (MIN.)
FLUSH TO INTERIOR
D
E
Minimum
-
36
43
914