5. Alignment and Adjustment
5-1 Reference
1) X-Point (Tracking center) adjustment, "Head switching adjustment" and "NVRAM option setting" can be adjusted with remote control.
2) When replacing the micom (IC601) be sure to adjust the "Head switching adjustment" and "NVRAM option setting".
3) When replacing the cylinder ass'y, be sure to adjust the "X-Point" and "Head switching adjustment".
4) Remote control used for same chassis as a accessory is available for all adjustments.
5) How to adjustment.
- Intermittently short-circuit the test point on Main PCB with pincets to set the adjustment mode.
- If the corresponding adjustment button is pressed, the adjustment is preformed automatically.
- If the adjustment is completed, be sure to turn the power off.
5-1-1 Location of adjustment button of remote control
Toshiba
X-Point (Tracking Center)
Adjustment
Head Switching Adjustment
NVRAM Option Setting
Fig. 5-1