Indesit K3G76/U Operating Instructions Manual page 13

Hide thumbs Also See for K3G76/U:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast (Large)(R)
100
Semi Fast
75
(Medium) (S)
Auxiliary (Small)
51
(A)
Triple Crown (TC)
130
Minimum (mbar)
Supply
Nominal (mbar)
Pressures
Maximum (mbar)
*
A 15°C e 1013 mbar-dry gas
G2.350 (GZ35)
p.c.s.
27.20 MJ/m³
G20 (GZ50)
p.c.s.
37,78 MJ/m³
G30 (GPB-B)
p.c.s.
49,47 MJ/Kg
S S
A
R
K3G76/U
K3G76S/U
KN3G76SA/CZ S
WARNING! The glass lid can break in if
it is heated up. Turn off all the burners
and the electric plates before closing
the lid. *Applies to the models with glass
cover only.
G30 (GPB-B)
Thermal
Thermal
By-pass
power
power
1/100
kW
kW
(p.c.s.*)
(p.c.s.*)
Reduc.
Nominal
(mm)
0,70
3,40
41
0,40
2,20
30
0,40
1,30
30
1,50
3,60
63
29
37
44
S S
A
TC
K3T76/U
K3T76S/U
KN3T76SA/U S
G20 (GZ50)
Nozzle
Flow*
Thermal
Nozzle
1/100
g/h
power
1/100
kW
(p.c.s.*)
(mm)
Nominal
(mm)
87
247
3,00
128
70
160
1,90
104
52
95
1,00
76
3,25
2x99
262
2x65
16
20
25
TABLE OF CHARACTERISTSICS
Dimensions (with
drawn guide rails)
Volume (with
drawn guide rails)
Maximum absorber
power:
Dimensions of the
lower compartment
Burners
Electric Plate
ENERGY LABEL
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
G2.350 (GZ35)
Flow*
Thermal
Nozzle
l/h
power
1/100
kW
(p.c.s.*)
Nominal
(mm)
286
3,00
158
181
1,90
143
(X)
95
1,00
106
309
2x138
3,25
10
13
16
width 39 cm
height 34 cm
depth 41 cm
59 l
5600 W
width 42 cm
height 23 cm
depth 44 cm
may be adapted for use with any type
of gas shown on the data plate, which
is located inside the flap or, after the
oven compartment has been opened,
on the left-hand wall inside the oven.
Rapid Ø 145 mm: 1500 W
Rapid Ø 180 mm: 2000 W
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
Convection;
Declared energy consumption for
Forced convection Class – heating
mode:
Baking
This appliance conforms to the
following European Economic
Community directives: 2006/95/EC
dated 12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments - 93/68/EEC
dated 22/07/93 and subsequent
amendments.
2002/96/EC
2009/142 of 30/11/09 (Gas)
1275/2008 (Stand-by/ Off mode)
GB
Flow*
l/h
397
251
132
430
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3g76s/uK3t76/uK3t76s/uKn3t76sa/u sKn3g76sa/cz s