R-Tech PLASMA 80HF Operation Instructions Manual page 7

Inverter plasma cutter
Table of Contents

Advertisement

7
smaller than recommended will result in 'nuisance' shut off from welder inrush currents even if
cutting at low amperages.
Failure to follow these instructions can cause immediate failure within the welder and void
machines warranty.
Turn the input power OFF at the mains switch & fuse box before working on this equipment.
Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge before
working inside this equipment. Do not touch electrically live parts
The Plasma 80HF Plasma Cutters require a 415V 3 Phase 50/60Hz supply. It requires an 17.6
Amp supply. It comes with a 3 metre mains cable attached.
Connect wires according to national coding.
Brown wire – Live
Blue wire – Live
Black wire- Live
Green/Yellow Wire – Earth (Ground)
Connecting to a mains electrical supply
THIS MACHINE IS OF AN INDUSTRIAL SPECIFICATION AND MUST BE
FITTED TO A 32AMP 415V MAINS INPUT
Connecting to an Engine Driven Generator
If connecting this Plasma Cutter to an engine driven generator please
ensure the following
Minimum Generator KVA Output – 19 KVA continuous
Generator to be fitted with AVR (automatic voltage regulation)
DO NOT USE ON A GENERATOR WITHOUT AVR
Connecting to a generator without the above minimum requirements will in-
validate your warranty.

Advertisement

Table of Contents
loading