technicians who will be happy to help you.
Please ensure machine is turned off before changing consumables
If cutting performance is poor you probably need to check / change the torch consumables.
To change the plasma cutting consumables carry out the following procedure
1.
Switch off machine
2.
Ensure torch has cooled down to avoid burns
3.
Unscrew the pink ceramic shroud
4.
Remove the silver cutting tip
5.
Check the condition of cutting electrode, replace cutting electrode if tip is worn 1-2 mm and
end is concave
6.
Fit new cutting electrode by screwing in and tweaking with pair of pliers – Do not over
tighten as this will cause thread / torch head damage
7.
Fit new cutting tip by screwing in and tweaking with a pair of pliers – Do not over tighten as
this will cause thread / torch head damage
8.
Refit pink ceramic cup by screwing on hand tight
9.
Turn machine back on and continue cutting