Page 1
Ref: 610MAN6K10K Rev 2 Issued: September 97 Installation and Operation Manual SOLA 610 6 & 10kV A 50/60 Hz Single Phase Uninterruptible Power System Save these instructions! This manual contains important instructions that should be followed during installation and maintenance of the UPS.
SOLA 610 UPS General Information 1.1 Table of Contents Page Number General Information Table of Contents ..............i Notice to UPS owners ............... ii Preface ..................iii FCC & Dept. of Communications Notice ........iv Safety Notice and Warnings ............v Installation Introduction and product description ..........
SOLA office. We encourage you to read this manual carefully in order to get full benefit from the features built into your SOLA product. It is recommended that you register your purchase by completing the warranty registration card.
SOLA 610 UPS General Information 1.3 Preface SOLA makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. SOLA shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Page 6
SOLA 610 UPS General Information 1.4 FCC & Department of C o m m u n ications Notice FCC NOTICE This equipment generates and uses radio frequency energy; and, if installed in a residential environment, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class A/B* digital device, pursuant to part 15 of the FCC rules.
The SOLA 610 is a physically small package. Do not install the unit in a high traffic area where people could trip on the unit, or its cables or cords.
Page 8
SOLA 610 UPS General Information 1.5 Safety Notices and Warnings (cont.) Safety Warnings (cont.) The SOLA 610 is intended for indoor use only. Do not install the unit next to open windows where uncontrolled environmental conditions could affect the unit.
UPS specifications, as detailed for each model. Your SOLA 610 is an advanced true on-line sine wave UPS with bypass line, utilising double conversion technology. The utility power enters the UPS where it is rectified to a DC voltage which will float charge the battery as well as run the DC to AC inverter.
SOLA 610 UPS Installation 2.3 Types of Loads The SOLA 610 UPS is designed to power all modern computer equipment “ loads” . The UPS output is specifically designed to work with switching power supplies found in today's microprocessor-based equipment.
Do not install the unit in any type of enclosure without first calling SOLA Technical Support. The unit must have unrestricted air flow. CAUTION The environmental specifications shown in Table 1 (below) show the temperature and hum idity lim its of the UPS.
SOLA 610 UPS Installation 2.7 Recharging the UPS Battery (cont.) Note The battery backup feature of the UPS is not available in this mode. See 3.1 “ Switching on the UPS” to enable the battery backup mode. In this mode, (and normal UPS operating mode) recharging occurs automatically and will take 10 hours if the batteries are completely discharged.
SOLA 610 UPS Installation 2.9 Inverter Shutdown Link Installation If your UPS has been delivered with the AS400 Card already installed, the inverter shutdown link Step 1 will be removed to avoid shipping damage. Make sure the green remote inverter shutdown link has a loop of wire in the terminals and firmly insert it into the receptacle as shown.
Each UPS is supplied with a package of CHECKUPS II® Advanced UPS communications software. This package includes the correct interconnection cable for your SOLA 610 UPS. If your computer does not have a DB9 Remote connector on the serial port, use a standard DB9-DB25 Shutdown adaptor, available at most computer accessory stores.
SOLA 610 UPS Operation 3.1 Switching on the UPS Load Level After completing the installation and battery and Runtime Overload Fault recharge, ensure the input circuit breaker and the lights output circuit breaker on the rear panel are both in the ON position.
The battery indicator will go out and the UPS will return to normal operation. 3. 4 Front Panel Indicators Your SOLA 610 UPS is fitted with 10 indicators to provide you with a simple but comprehensive explanation of the UPS status, The function of these LED indicators are detailed below:-...
SOLA 610 UPS Optional Features 4.1 External Battery Options External battery packs may be connected to the SOLA 610 UPS. The standard battery packs available are listed below: * R u n tim e w ith U P S a n d a d d itio n a l battery...
SOLA 610 UPS Optional Features 4.2 Installing the CheckUPS II® Software Each Sola 610 UPS is supplied with CheckUPS II® Software, a sophisticated UPS Monitoring and orderly unattended system shutdown utility for most popular operating systems. The CheckUPS II® Suite is contained on the CD-ROM in the software pack along with a special cable for use with your SOLA 610.
Page 20
SOLA 610 UPS Optional Features 4.2 Installing the CheckUPS II® Software (cont.) If your UNIX system cannot mount and read the CD-ROM, please copy/transfer from a DOS/Windows system onto your UNIX system: SOLA UPS users: D:\UNIX\SOLAUNIX.TAR D:\UNIX\UNIXINST When you have the files on your UNIX system (preferably...
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® Monitoring Center Configuration The monitoring center window provides you with a view of current UPS values. Each time CheckUPS II® Advanced is started the monitoring center window displays. The reading values and meter graphs are fully configurable and can display any values provided by the UPS.
Page 22
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) M e ters The Meters group allows you to graph three values from a list of UPS values. If you would like to change a meter or the properties of a meter, just point to the meter and click. The Meter Configuration window displays.
Page 23
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Event Configuration CheckUPS II® Advanced offers you complete control over UPS system events. The number of events available varies depending on your UPS model. The actions include: operating system and UPS Shutdowns , event Logging, message Broadcasting , administrator Paging, and executing Commands.
Page 24
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Event Action Configuration Select an event from the Choose Event list box. The actions include: operating system and UPS Shutdowns , event Logging, message Broadcasting , administrator Paging, and executing Commands.
Page 25
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Logging If you haven’ t already selected Configure|Action… from the main menu bar, please select it now . In the Event Action Configuration window, click the Logging command button to display the Event Logging Configuration window.
Page 26
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Paging If you haven’ t already selected Configure|Action… from the main menu bar, please select it now . In the Event Action Configuration window, click the Paging command button to display the Paging Configuration window.
Page 27
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Paging (cont.) When you are finished with Modem Alert Configuration, click the OK command button. If you want to abandon changes, click Cancel . Common Modem Commands See your modem user’ s manual for a complete list of dial modifiers.
Page 28
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) E m a il Email is only available for Windows 95®. If you haven’ t already selected Configure|Action… from the mainmenu bar, please select it now . In the Event Action Configuration window, click the Email command button to display the Email Configuration window.
Page 29
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) C o m m a n d s If you haven’ t already selected Configure|Action… from the main menu bar, please select it now . In the Event Action Configuration window, click the Commands command button to display the Command Script Configuration window.
Page 30
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Data H istory G raph After some data accumulates, you can view a history graph of one of the data types. To display the graph, select the View|Graph… menu option.
Page 31
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Data Log Viewer After data accumulates, you can view the data log. To display the log, select the View|Data Log… menu option. Use the vertical and horizontal scroll bars to view all of the rows and columns in the table.
Page 32
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) Scheduling CheckUPS II® Advanced allows you to schedule operating system and UPS shutdown and restart, and UPS self tests. To schedule actions, select UPS Control/Scheduled… from the menu bar. The Calendar Overview window provides you with monthly calendar of scheduled actions.
Page 33
SOLA 610 UPS Optional Features 4.3 Operating CheckUPS II® (cont.) UPS Control Options UPS control options are special commands sent to the UPS. These commands are dependent on the model of UPS. To display the Additional UPS Control Options window, select the menu option: UPS Control|Control Options…...
SOLA 610 UPS Optional Features 4.4 Installation and Operation of the AS400® card option Output 2 (ES 2 Pin connector) A plug with link is supplied with the AS400® card option. This plug must be installed for normal operation. If this plug is removed, the load will be transferred to bypass.
SOLA 610 UPS Optional Features 4.5 Installation and Operation of the SNMP Card Option You may wish to connect your UPS to a network management system using SNMP. This will require the purchase of the SNMP Adaptor card option (Part No. 0610-SNMP-00) which will install in the communications slot on the rear of the UPS.
The warranty on this product will be affected if the unit is improperly stored. 5.2 M a intenance and Cleaning Your SOLA 610 UPS requires little or no maintenance. Occasionally, the input and output cabling should be inspected for signs of damage and repaired if necessary.
Please note the following information when you call for service: Model number, Serial number. Date of problem. Full description of problem. SOLA Customer Service Centre Locations are listed on the rear page. Troubleshooting Chart Problem Possible Cause Action to Take...
SOLA 610 UPS Maintenance and Warranty 5.4 Model Specifications “A” Model (Australian Version) Input Input Voltage Range: 240 Volts +10%, -20% Input Frequency Range: 50/60 Hz + 5% (Auto Selecting) Input Current (Nom. Full Load): 6000VA 10000VA Connection: Hardwired Output...
Page 39
SOLA 610 UPS Maintenance and Warranty 5.4 Model Specifications (cont.) All Models - Physical U P S U n i t Model W idth (m m ) Depth (m m ) Height (m m ) Weight (kg) 0610-6000A 0610-010KA B a t t e r y P a c k s...
5.5 Warranty Australia ONLY This Warranty is subject to Sola's standard Conditions of Sale which govern all sales of products by Sola Australia Ltd. Sola products, in general, are warranted against failure due to faulty materials and/or workmanship for a period of one year from despatch date (ex Sola store) as per invoice.
For proper handling upon receipt at SOLA, the R/A Number must be clearly placed in several locations on the outside of the package. SOLA will not be responsible for damage to returned goods that have not been properly packaged or damage exceeding normal wear and tear.
Page 42
In addition, SOLA/BEST field sales offices are conveniently located to provide prompt attention to customer needs. Call SOLA/BEST direct to find the closest authorised distributor.
Need help?
Do you have a question about the 610 and is the answer not in the manual?