9-3 Troubleshooting for flow sensor dryer

• Check the Error Code before you call for service
Error Code
tE1
or tE2
HS
PS
or PF or nP
The display
TM
FLOW SENSE
indicator shows
four bars during
the drying cycle
or the display
drying.
• Check the duct condition
If the FLOW SENSE
LED is turned on, check the
TM
exhaust system for restrictions and damage. Repair or
replace the exhaust system as needed.
Restricted or Blocked Air ow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
Too many elbows or
transition duct
exhaust too long
Possible Causes
• Temperature sensor failure
• Humidity Sensor failure.
• Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
many turns/restrictions.
ductwork due to lint buildup or
debris.
restriction in the external dryer
venting.
• Check the power supply or the connection of
power cord to the terminal block. Refer to the
Connecting electric dryers section of this
manual for complete instructions.
• Reset circuit breaker or replace fuse. Do not
increase the fuse capacity. If the problem is a
circuit overload, have it corrected by a quali-
Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted exhaust
is dangerous and could result in a re or other
property damage.
Check the outside dryer vent while the dryer is
operating to make sure there is strong air ow.
If ther exhaust system is extremely long, have it
repaired or rerouted.
Keep the area around the dryer clean and free
of clutter.
Check the vent hood for damage or lint clogging.
Make sure the area around the vent hood is clear.
Install a shorter or straighter duct run. See the
Instructions.
Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying
times may be longer.
If exhaust restrictions are sensed by the
FLOW SENSE
on for two hours after the end of the cycle.
Opening the door or pressing the POWER button
will turn o the display.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
25
Solutions
TM
system, the indicator will remain
Lint buildup
or blockage
Crushed or
damaged
exhaust