LG DLEX3250 Series Service Manual page 17

Electric & gas dryer
Hide thumbs Also See for DLEX3250 Series:
Table of Contents

Advertisement

Component
13. Outlet Thermostat
(Auto reset)
• Check Top Marking:
N95
14. Outlet Thermostat
(Manual reset)
• Check Top Marking:
N110
Test Procedure
Measure resistance of terminal
to terminal
Open at 203 ± 7°F (95 ± 5°C)
Close at 158 ± 9°F (70 ± 5°C)
Measure resistance of terminal
to terminal
Open at 212 ± 12°F
(110 ± 7°C)
Manual reset
Check result
Resistance value ≒ ∞
Continuity < 1Ω
If thermal fuse is open must
be replaced
Resistance value ≒ ∞
Continuity < 1Ω
17
Remark
• Gas type
• Gas funnel
• Gas type
• Gas funnel