7-1-5 BUZZER SOUND
1. When the button on the front Display is pushed, ÒDing-Ó sound is produced and it works as follows.
7-1-6 DEFROSTING
1. The defrosting is performed each time when the total running time of the compressor reaches 7 hours.
2. After the power is turned on (or restored after a power failure), the defrosting starts when the total running time of the
compressor reaches 4 hours.
3. When the temperature of the defrosting sensor reaches 13 ¡C or above, the defrosting stops. If the temperature does not
reach 13 ¡C in 2 hours after the defrosting starts, the defrosting error code is displayed.
(Refer to 7-1-10. Error Diagnostic Mode.)
4. With the defective defrosting sensor (cut or short-circuited wire), the defrosting will not be performed.
7-1-7 SEQUENTIAL OPERATION OF ELECTRIC COMPONENTS
The electric components, such as the comp, defrosting heater, and cooling fan, start sequentially to avoid the noise and
damage to the part, which may result from the simultaneous start of various components on turning the power on or after
the completion of a test.
Condition of Operation
If the temp of the defrosting
sensor is 45 ¡C or above
(For the initial use after the
purchase or grounding)
If the temp of the defrosting
sensor is below 45 ¡C
(After a power failure or SVC)
When returned from the T est mode
POWER
in 0.5 sec
ON
POWER
in 0.5 sec
ON
COMP
in 0.5 sec
ON
ALL LOADS
in 7 min
OFF
- 20 -
Operating Sequence
COMP
in 0.5 sec
ON
DEFROSTING
in 5 sec
HEATER ON
COOLING FAN
in 0.5 sec
ON
COMP
in 0.5 sec
ON
COOLING FAN
ON
DEFROSTING
HEATER OFF
COOLING FAN
ON