6-2 PTC AND OLP
Normal operation of
Compressor is
impossible or poor.
Separate the PTC from
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
T ester or Wheat stone
bridge. (Figure 22)
Separate the OLP
from Compressor and
check resistance
value between two
terminals of OLP with
a T ester. (Figure 23)
4
3
Figure 22
Observation value at
220V/50Hz : 47‰– 30%
220 - 240V/50Hz : 47 ‰– 30%
110 -115V/60Hz : 6.8 ‰– 30%
220V/60Hz : 47‰– 30%
127V/60Hz : 22‰– 30%
The resistance value is
0 or several
hundreds ‰or infinity.
YES
Check another
electric components.
NO
Replace OLP .
Figure 23
- 13 -
Check another
electric components.
Replace
PTC.