Fujitsu MHW2160BH Product Manual page 99

Hide thumbs Also See for MHW2160BH:
Table of Contents

Advertisement

- X'05':
- X'06':
(2)
Features Field (exp)
The Features Field provides specific feature to a command. For instance, it is used
with SET FEATURES command to enable or disable caching.
(3)
Sector Count Field (exp)
The Sector Count Field indicates the number of sectors of data to be transferred in
a read or write operation between the host system and the device. When the value
in this field is X'00', the sector count is 256. With the EXT system command, the
sector count is 65536 when value of the Sector Count Field is X'00' and that of the
Sector Count Field (exp) is X'00'.
When this field indicates 0 at the completion of the command execution, this
indicates that the command is completed successfully. If the command is not
completed successfully, this field indicates the number of sectors to be transferred
to complete the request from the host system. That is, this field indicates the
number of remaining sectors that the data has not been transferred due to the error.
However, as of the last sector of PIO transfer, SC=1 indicates the normal
completion.
The contents of this field also have other definitions (Refer to 5.4)
(4)
Sector Number Field (exp)
The contents of this field indicates the starting sector number for the subsequent
command. The sector number should be between X'01' and [the number of
sectors per track defined by INITIALIZE DEVICE PARAMETERS command.
Under the LBA mode, this field indicates LBA bits 7 to 0. Under the LBA mode
of the EXT system command, LBA bits 31 to 24 are set in the Sector Number
Field, and LBA bits 7 to 0 are set in the Sector Number Field (exp).
(5)
Cylinder Low Field (exp)
The contents of this field indicates low-order 8 bits of the starting cylinder address
for any disk-access.
At the end of a command, the contents of this field are updated to the current
cylinder number.
Under the LBA mode, this field indicates LBA bits 15 to 8. Under the LBA mode
of the EXT system command, LBA bits 39 to 32 are set in the Cylinder Low Field,
and LBA bits 15 to 8 are set in the Cylinder Low Field (exp).
C141-E245
Reading the system area is abnormal.
Calibration is abnormal.
5.2 Logical Interface
5-25