Standby (X'96' Or X'e2') - Fujitsu MHW2160BH Product Manual

Hide thumbs Also See for MHW2160BH:
Table of Contents

Advertisement

Interface

(12) STANDBY (X'96' or X'E2')

Upon receipt of this command, the device enters the standby mode. If the device
has already spun down, the spin-down sequence is not implemented.
If the Sector Count field has a value other than "0," the APS timer is set when the
command is received. When the device receives the command involving a seek
such as media access command, the device processes the command after transition
to Active mode. After that, the device enters the command waiting state, and the
timer starts to count down. If a command is not received within the period
specified as the APS timer value, the device automatically enters Standby mode.
If the Sector Count field value is "0" the APS timer is disabled when the command
is received.
Under the standby mode, the spindle motor is stopped. Thus, when the command
involving a seek such as READ SECTOR(s) command is received, the device
processes the command after driving the spindle motor.
Error reporting conditions
(1) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM
DH
CH
CL
SN
SC
FR
At command completion (Shadow Block Registers contents to be read)
ST
DH
CH
CL
SN
SC
ER
5-50
X'96' or X'E2'
x
x
x
x
xx
xx
xx
Period of timer
xx
Status information
x
x
x
x
xx
xx
xx
xx
Error information
xx
xx
C141-E245